Linear or Circular Polarization?

Linear polarization keeps the electric field oscillating in a fixed direction; circular polarization makes it rotate. Linear is chosen when both ends hold a stable orientation, and circular when the orientation varies or rotation must be tolerated.

What each one is

Polarization describes the path traced by the electric field vector in a plane perpendicular to the direction of propagation. In linear polarization, the field oscillates along a line, for example vertical or horizontal. In circular polarization, two orthogonal components of equal amplitude, a quarter cycle out of phase, make the vector rotate at constant speed, clockwise or counterclockwise. If the amplitudes differ, the polarization is elliptical.

The effect of misalignment

A linear link transfers maximum power only if both antennas have the same orientation. When they are rotated relative to each other, the received power decreases with the square of the cosine of the angle, until it is almost zero at 90 degrees. In a circular link, rotating an antenna about its axis does not change the received polarization, so that rotation produces no loss.

When each one is the better choice

  • Linear: fixed terrestrial links, where the antennas are aligned during installation, and cases where the separation between orthogonal polarizations is used to reuse the channel.
  • Circular: communications with satellites or mobile platforms, where the relative orientation changes, and environments where sensitivity to Faraday rotation in the ionosphere is to be reduced.

A detail about the sense of rotation

Two circular antennas must have the same sense in the correct reference frame. On reflection from a surface the sense is reversed, which is why a receiving antenna of the same sense as the transmitting antenna rejects part of the single-reflection echoes. This reduces multipath in some environments.

What the engineer sees when measuring

The quality of a circular antenna is characterized by the axial ratio: the ratio between the axes of the polarization ellipse. A value close to unity indicates almost perfect circular polarization, and quality usually worsens off-axis and at the band edges.

The cost of circular polarization

A circular antenna receiving from a linear antenna has a theoretical loss of half the power, regardless of its orientation. If the system communicates with linear equipment, that loss must be included in the link budget.