How Is the Electrical Length of an Antenna Cable Measured?

The electrical length of a cable is measured with an analyzer in the frequency or time domain: the signal delay or the phase shift into an open or shorted load is determined and then related to the physical length through the velocity factor.

Electrical length versus physical length

A signal travels more slowly through a coaxial cable than in a vacuum. The ratio of the two speeds is the velocity factor, which depends on the dielectric. That is why the electrical length, expressed as a delay or as a fraction of a wavelength, does not match the physical length. The same piece of cable can be a quarter wave at one frequency and a half wave at another.

Common methods

  • Time-domain reflectometry: a pulse is sent, or synthesized from a frequency sweep. With the far end open or shorted, the reflection returns after a round trip. The measured delay, divided by two, gives the one-way delay.
  • Phase measurement versus frequency: a vector analyzer measures the transmission or reflection phase. The slope of phase against frequency determines the group delay, from which the electrical length is obtained.

From delay to physical length

If the velocity factor of the cable is known, the physical length is estimated by multiplying it by the speed of light and by the delay. If the physical length is known instead, the measurement makes it possible to verify the actual velocity factor. This is useful for locating faults: once the correct factor is entered, the distance shown by the instrument matches the actual location of the damage.

An application example

In antenna arrays or phase-coherent systems, the cables feeding each element must have the same delay, not necessarily the same physical length. Each cable is measured and the phase shift compared; if there are differences, they are corrected with an additional length of cable.

Precautions

  • Calibrate at the end of the test cable to remove the effect of the adapters.
  • Measure with the cable extended and without tight bends, because deformation alters the impedance.
  • Keep in mind that the velocity factor varies slightly with frequency and temperature.