Practical answer
When two antennas share a structure, the transmitter on one can saturate or interfere with the receiver on the other. Isolation quantifies that coupling. It is measured with a two-port network analyzer: one antenna is connected to each port and the transmission parameter (S21, or S12) is read, which shows how much signal gets from one to the other. Isolation is the attenuation between the two ports, normally expressed in decibels.
Setup and procedure
- Calibrate the two-port analyzer at the ends of the cables that will connect to the antennas, to remove their losses.
- Install the antennas in their actual position, with their mounts and the structure they are fastened to.
- Sweep the operating band of both antennas and record the transmission.
- Check that the result does not change when the cables are moved, which would indicate coupling through the shield.
What the value depends on
- Separation and orientation: greater distance reduces coupling, and pointing the pattern nulls toward each other reduces it further.
- Polarization: orthogonal polarizations provide better isolation.
- Nearby structure: the mast, the rooftop or a metal chassis can conduct and reflect energy between the antennas.
- Frequency: coupling changes with the band, so it is evaluated across the full range of use.
What the engineer sees
The transmission curve shows ripple caused by reflections and resonances in the structure. A region where the isolation drops marks the frequency at which interference between equipment will be greatest. If both antennas operate in the same band, the result must be compared with the protection the receiver needs against the neighboring transmitter.
When another solution is advisable
If the measured isolation is insufficient, the separation can be increased, the orientation changed or filtering added at the receiver. This should be verified with the actual equipment running, because antenna isolation is only one part of the protection against interference.