How is antenna gain measured with three antennas?

The three-antenna method obtains the gain of three unknown antennas by measuring the transmission between them in pairs and solving a system of three equations, without needing an antenna of known gain.

The central idea

Measuring gain by comparison requires a reference antenna of known gain. The three-antenna method eliminates that need. Three different pairs are measured (A with B, A with C and B with C) and the Friis transmission equation is applied to each pair. Each measurement relates the product of two gains to the distance, the wavelength and the ratio of received to transmitted power. With three equations and three unknowns, the system is solved and the gain of each antenna is obtained.

Why it works

The product of the transmit and receive gains appears in each equation. When expressed in decibels, products become sums, and the system reduces to adding and subtracting the measured transmission losses. It is an absolute method: the gain comes from the physics of the link and not from an external standard.

Conditions that must be met

  • Far field: the separation between antennas must exceed the far-field distance of the largest one, so that the Friis equation is valid.
  • Alignment: each pair must point in the direction of maximum radiation.
  • Polarization: the two antennas in each pair must share the same polarization, or the difference must be corrected.
  • Controlled environment: reflections from the ground or walls add to the direct signal and bias the result, which is why an anechoic chamber or a site with well-treated reflections is used.

Necessary corrections

The impedance mismatch of each antenna with its line or with the instrument must be taken into account, because part of the power is reflected and does not contribute to the link. The losses of cables and adapters, which are measured separately, are also compensated.

What to check first

Before solving the system, check that the distance is the same in all three measurements and that the received signal does not vary when the antennas are moved slightly, which would indicate reflections. The method applies to any type of antenna as long as the above conditions are respected.