A way of looking at reception
When a wave passes a receiving antenna, the antenna captures part of the power crossing the space around it. Effective area expresses that capability as a surface: the received power is the incident power density multiplied by that area. It is not a physical size, but it is a way of comparing how well each antenna captures power.
Relationship with gain
For an antenna with no polarization or matching losses, the effective area is the square of the wavelength, multiplied by the gain and divided by four pi. This relationship comes from reciprocity: an antenna that transmits with a certain gain receives with the corresponding effective area. It has two consequences:
- For equal gain, an antenna for a higher frequency has a smaller effective area, because the wavelength is shorter.
- To capture the same power at higher frequencies, more gain is needed, that is, a more directive antenna.
Relationship with physical area
In aperture antennas, such as a parabolic reflector or a horn, the effective area is a fraction of the physical area of the aperture. That quotient is called aperture efficiency, and it is reduced by feed spillover, blockage, surface errors and non-uniform illumination. A wire antenna has no obvious physical aperture, and its effective area can be larger than its physical cross section.
Use in link calculations
The Friis transmission formula can be written with gains or with effective areas. With areas, the received power depends on the product of the effective areas of the two antennas, divided by the square of the distance and the square of the wavelength. This shows why, at higher frequencies, a link pays more in free-space loss if fixed-gain antennas are used, and why with fixed-aperture antennas the gain grows with frequency.
How the idea is applied
To estimate how much power an antenna captures in a known field, multiply the power density by the effective area and correct for polarization mismatch and impedance mismatch losses. If the received power is much lower than expected, the usual causes are incorrect pointing, cross-polarization or a mismatch at the connector.