Three regions around an antenna
Close to the antenna, the fields are complicated. Energy is stored and returned, as in a reactive component, and the angular distribution varies with distance. Three regions are distinguished:
- Reactive near field. Right next to the antenna; energy storage dominates and the fields are not a propagating wave.
- Radiating near field or Fresnel region. Radiation predominates, but the shape of the pattern still changes with distance.
- Far field or Fraunhofer region. The angular pattern stabilizes, the field decays in inverse proportion to distance and the wave is locally plane, with the electric and magnetic fields perpendicular to each other and to the direction of propagation.
The transitions between regions are gradual, not abrupt boundaries.
How to estimate where it begins
For antennas that are large compared with the wavelength, a widely used criterion sets the boundary at twice the square of the largest dimension of the antenna, divided by the wavelength. This distance grows rapidly with antenna size and with frequency, so for large-aperture antennas at microwave frequencies it can reach tens of meters or more. For small antennas, other criteria dominate, and the distance must also be greater than a few wavelengths.
Why it matters for measurement
If the pattern or gain is measured too close, the phase of the wave arriving at the antenna is not uniform across its aperture. The result is a broadened pattern, filled-in nulls and an underestimated gain. The distance criterion aims to limit that phase variation to a tolerable value.
When the required distance does not fit in the test enclosure, there are alternatives: using a reflector that collimates the wave over a short distance, or measuring the near field over a surface and calculating the far field by a mathematical transformation.
When the criterion does not apply
The classic criterion assumes antennas with large dimensions compared with the wavelength. It should not be applied without care to small antennas, to large-aperture arrays focused at finite distances, or to measurements where the immediate surroundings alter the distribution. In those cases, the criterion specific to the application is used, or the far-field condition is confirmed by checking that the pattern does not change when the distance is varied slightly.