Antenna polarization describes the orientation and time behavior of the electric field vector of the wave it radiates. It can be linear, circular or elliptical, and the transmitting and receiving antennas must match to avoid losing signal.

What is polarized

An electromagnetic wave has an oscillating electric field. Polarization is the figure traced by the tip of that vector, over time, in a plane perpendicular to the direction of propagation. The antenna determines that figure when transmitting, and selects a preferred polarization when receiving.

Types

Type Field behavior
Linear Always oscillates along the same line; called vertical or horizontal depending on its orientation relative to the ground
Circular Rotates at constant amplitude; right-hand or left-hand depending on the sense
Elliptical The general case; the tip of the vector traces an ellipse

Linear and circular polarization are special cases of elliptical polarization. In practice an antenna is never perfectly pure: a real circular antenna emits a very flattened or nearly round ellipse. The axial ratio, the ratio of the major to the minor axis of the ellipse, measures that defect; it equals one in the ideal circular case and grows toward the linear case.

Polarization mismatch

A receiving antenna captures all the available power only when its polarization matches that of the incident wave. If it does not match, there is a loss:

  • Two linear antennas tilted relative to each other lose power as they become misaligned, and at ninety degrees the loss is theoretically total; in practice it is limited by the purity of the antennas and by reflections.
  • A circular antenna receiving a linear wave captures approximately half the power, about three decibels less, whatever the orientation of the linear wave.
  • Two circular antennas of opposite sense do not couple well.

What the engineer observes

When measuring a link, an unexpected drop in signal may be due to an antenna being rotated. For linear antennas on point-to-point links, measurements are made with both polarizations to check cross-polarization discrimination. A reflection reverses the sense of a circular wave, so a circular antenna of the same sense as the transmitter may receive the reflected signal poorly, which is used to reduce multipath.

When specifying or checking an antenna, it is advisable to state the polarization type, the sense in the circular case and the band over which it holds.