What is antenna gain?

Antenna gain is the ratio between the power an antenna radiates in a given direction and the power an ideal isotropic antenna fed with the same power would radiate, including the antenna's own losses. It does not create power: it concentrates it in certain directions.

Concentrating, not amplifying

An antenna is a passive element and cannot deliver more power than it receives. What it does is distribute that power unevenly in space. If it concentrates the radiation in one direction, in that direction it appears stronger than a source radiating equally in all directions, at the cost of less radiation in other directions. Gain measures that concentration, referred to an isotropic reference antenna.

Relationship with directivity and efficiency

Directivity describes only the shape of the radiation distribution: how concentrated it is. Gain adds the antenna’s losses due to conductor resistance and dielectrics. Therefore:

gain = radiation efficiency × directivity

A highly directive antenna with high losses has a lower gain than its shape suggests. Gain as usually stated does not include the impedance mismatch between antenna and line, which is accounted for separately in what is called realized gain.

Units

Unit Reference
dBi Isotropic antenna
dBd Half-wave dipole

A half-wave dipole has a gain of approximately 2.15 dB over the isotropic antenna, so a value in dBd is converted to dBi by adding that amount. When comparing specifications, it is advisable to check which of the two is used.

What is seen in practice

  • The gain stated on a datasheet is usually the maximum, in the direction of the main lobe; in other directions it is lower, and it is known from the radiation pattern.
  • Higher gain means a narrower beam: the antenna points better, but tolerates a pointing error less well.
  • It varies with frequency. The gain specified at the center of the band may be lower at the edges.

How it is measured

It is measured in the far field, either by comparison against an antenna of known gain or by absolute methods that use several antennas. The results depend on polarization, distance and reflections from the surroundings, so the measurement environment must be controlled.

The gain of an antenna determines how much effective power is radiated or received, and it is one of the quantities added in a link budget.