Origin and purpose
Some processes generate or use radio frequency without transmitting information: microwave heating, high-frequency plastic welding, drying, certain medical diathermy equipment and plasma generation. This equipment emits energy that can interfere with radio services. To contain the problem, the ITU Radio Regulations designate certain bands for this use, so that the unwanted energy stays concentrated in them and does not disturb communication services.
The shift toward communications
Because these bands were already subject to industrial emissions, the authorities allowed low-power communication equipment to use them without an individual license, on condition that it accept interference. As a result, technologies such as Wi-Fi, Bluetooth and many remote controls, sensors and low-power networks operate in ISM bands. The exact conditions (permitted power, modulation, duty cycle) are set by each country’s telecommunications authority and vary between regions.
What the lack of protection implies
A communication device in an ISM band has no right to protection against interference from ISM equipment or from other users of the band. It is a shared band and therefore a congested one. An engineer measuring a wireless connection in this band should expect other emitters on the same channel: ovens, other links, industrial equipment and devices from other networks.
What is seen on a spectrum analyzer
- A band occupied by several carriers from different technologies, with a raised background level.
- Emissions from ISM equipment that spread irregularly, sometimes in the form of pulses or sweeps.
- Variations over time: occupancy changes, so it is advisable to measure with max hold, or with spectrogram displays, over sufficiently long periods.
Design implications
Systems in ISM bands usually employ coexistence techniques such as frequency hopping, spread spectrum or listening to the channel before transmitting. Anyone designing or evaluating such a system must check its immunity to strong nearby emissions, and that its out-of-band emissions do not encroach on neighboring services.
The specific frequencies of each ISM band, as well as the power limits and conditions of use, must be consulted in the ITU regulations and in the current regulations of the country where the equipment operates.