Definition
The decibel expresses a ratio, not an absolute quantity. For powers, the ratio in decibels is ten times the base-ten logarithm of the quotient of the two powers. For voltages or currents, with the same impedance at both points, it is twenty times the logarithm of the quotient, because power is proportional to the square of the voltage. Both expressions give the same result for the same physical power ratio.
Why it is convenient in RF
- Enormous range. A single measurement can contain a strong signal and another one millions of times smaller. On a linear scale the small one is invisible; in decibels, both fit on the same plot.
- Cascading. When a signal passes through several stages, the total ratio is the product of the individual ratios. In decibels, it is the sum. Calculating the budget of a link or a measurement chain comes down to adding and subtracting.
- Perception and resolution. Small relative differences, such as those of a return loss close to ideal, are easier to see on a logarithmic scale.
Useful equivalents
| Power ratio | Decibels |
|---|---|
| Equal | 0 dB |
| Approximately double | about 3 dB |
| Ten times | 10 dB |
| One hundred times | 20 dB |
| Half | about −3 dB |
A positive value is gain and a negative one is loss. In voltage, a factor of two corresponds to about six decibels, not three. This difference explains many conversion errors.
How to interpret it on the screen
When a return loss plot shows a higher value in decibels, there is less reflection: return loss is the ratio of incident to reflected power, so a larger number means a better match. An insertion loss of a few decibels means that a significant fraction of the power is lost, not a small one.
References and suffixes
The decibel on its own is only relative. To state an absolute level, a reference is added as a suffix: dBm if the reference is one milliwatt, dBW if it is one watt, dBc if it is the carrier, dBi if it is an isotropic antenna. Adding two absolute levels in decibels is an error: the powers are added in linear units and then converted back. Adding an absolute level to a gain or loss in dB, on the other hand, is correct and gives an absolute level.