How Is the Integrity of a Long Transmission Line Verified?

Return loss and insertion loss measurements across the whole band are combined with time-domain fault location, which shows where each reflection occurs along the line.

What you are looking for

A long line can fail in several ways: damaged connectors, crushed or kinked sections, moisture in the dielectric, deteriorated joints or an unplanned change of cable type. All of them modify the impedance at a point and reflect part of the signal. Verifying integrity means detecting those reflections and locating them.

Frequency-domain measurement

With a network analyzer connected to one end and the line terminated in its normal load, return loss indicates how well matched the assembly is. Poor return loss or pronounced ripple points to discontinuities. If both ends are accessible, insertion loss measures how much the line attenuates in the band of use, and it is compared with what is expected for that cable and its length. Higher loss than expected suggests water, damage or deficient connectors.

Fault location

To find out where the problem is, a distance-to-fault measurement is used. It can be done in two ways: with a time-domain reflectometer, which sends a pulse and observes the echoes, or with a network analyzer that measures in frequency and transforms the result to the time domain. In both cases, the round-trip time is converted to distance using the propagation velocity of the cable, given by its velocity factor. If that factor is wrong, the distances will be wrong in proportion.

Two relationships guide the procedure:

  • The resolution for separating two nearby faults improves as the sweep bandwidth increases.
  • The maximum distance that can be explored depends on the start frequency and the frequency step, and on the cable loss: a distant fault produces an echo weakened by the round-trip attenuation.

An example reading

In a distance trace, a discontinuity appears as a peak at a certain distance; an open end reflects with the same sign as the incident signal, a short with the opposite sign, and a parasitic capacitance or inductance can be recognized by the shape of the peak. A peak at a point where a connector is known to exist is to be expected; a peak where there is none deserves inspection.

Good practices

  1. Calibrate at the measurement end, to exclude test cables and adapters.
  2. Save a reference trace when the line is in good condition and compare against it later.
  3. Set the velocity factor according to the cable and the known physical length.
  4. Verify the path with the far end open and shorted, to validate the distance scale.