What Does the IEEE 1785 Standard for Waveguides Define?

IEEE 1785 is a family of standards that establishes band designations, dimensions, flange interfaces and performance requirements for metallic rectangular waveguides at very high millimeter-wave and submillimeter-wave frequencies.

Why waveguides need a standard

In a rectangular waveguide, the internal dimensions set the cutoff frequency and the single-mode band. At very high frequencies, those dimensions are fractions of a millimeter, and small differences between manufacturers change the response appreciably. Without a standard, a component from one manufacturer might not mate with another’s flange, or might not agree in band and reflection.

General scope

The IEEE 1785 family deals with metallic rectangular waveguides and their interfaces for the highest microwave frequency range, extending into millimeter and submillimeter waves. Its parts essentially address two matters:

  • Designation and dimensions. A system for naming the bands and setting the cross-section dimensions and their tolerances, so that the same name means the same waveguide.
  • Performance and interfaces. Requirements for flanges and how they mate, and performance specifications for waveguides, such as loss and reflection, applicable to these small sizes.

It does not replace the waveguide standards for lower frequencies, which follow other series. It is a complement for the high end, where earlier standards did not consistently cover the necessary flanges and tolerances.

What the engineer observes in practice

The dimensions determine what is measured. If a flange has a small lateral misalignment, or there is a step between the apertures of two waveguides, a reflection appears as ripple in the return loss, and it grows with frequency because the step is a larger fraction of the wavelength. Standardized interfaces aim to keep those steps small and repeatable, which is especially important when calibrating a network analyzer with frequency extenders.

It also helps in knowing which waveguide to use for each range: the designation indicates the frequency band in which the waveguide operates in single mode, above cutoff and below the onset of the next mode.

How to use it

This guide describes only the general scope. Dimension values, tolerances and performance limits, as well as the numbering of its parts, must be consulted in the current edition of the standard and its associated documents. If a component is specified as compliant with it, confirm which part and edition are declared.