The role of each one
An attenuator reduces the power of a signal by a known amount. The fixed type has a single value and is built with a resistive network with no moving parts. The variable type can be stepped, with sections that are switched, or continuous, with an adjustable element.
When the fixed type is the better choice
- Protection and level. Ahead of the input of an analyzer or power meter, to keep the signal within the safe, linear range of the receiver.
- Improved matching. A reflection passing through an attenuator does so twice, there and back, so its level falls by twice the attenuator’s value in decibels. A fixed attenuator between two poorly matched elements reduces the ripple caused by multiple reflections.
- Repeatability. With no mechanism, its value changes little with use and over time.
When the variable type is the better choice
When you need to sweep the input level of a device, find the compression point, adjust levels between tests or equalize levels without changing components. Stepped types have better repeatability than continuous ones, but both have a minimum loss even when set to zero, and their matching can vary with the setting. Their accuracy is usually lower than that of a characterized fixed attenuator.
Comparison
| Aspect | Fixed | Variable |
|---|---|---|
| Repeatability | High | Lower, depends on the mechanism |
| Matching | Stable | Can change with the setting |
| Flexibility | A single value | Adjustable |
| Minimum loss | The nominal value | Present even at the minimum setting |
When it does not apply or is best avoided
An attenuator ahead of the first active element of a receiver degrades the signal-to-noise ratio: the noise figure of the chain increases in proportion to the added loss. If the goal is to measure a signal close to the noise floor, use the minimum necessary. In addition, every attenuator must be kept within its maximum power; an overloaded attenuator changes value or is damaged.
Any attenuator used in the chain must be characterized in the working band, because its value and matching vary with frequency. If it is not, that uncertainty carries over into the final measurement.