What Are a Ferrite Circulator and Isolator?

They are non-reciprocal three-port devices that use magnetized ferrite to make the signal circulate in only one direction from port to port; an isolator is a circulator with one port terminated in a load, which passes the signal in one direction and absorbs the reverse signal.

What makes them special

Most passive RF components are reciprocal: they transmit the same way in one direction as in the other. A circulator is not. It uses a ferrimagnetic material, ferrite, under a static magnetic field produced by a magnet. Under that condition, the ferrite responds differently to waves according to the direction of rotation of their field, and this can be exploited so that energy flows in one direction and not in the other.

The circulator

It has three ports (versions with more exist). A signal entering port 1 exits port 2, a signal entering port 2 exits port 3, and a signal entering port 3 exits port 1. In the opposite direction there is high isolation. It is used, for example, to share an antenna between a transmitter and a receiver: the transmitter signal goes to the antenna and the received signal goes to the receiver, without passing directly between them.

The isolator

If a matched load is connected to the third port of a circulator, the result is a two-port component that passes the signal from input to output with little loss and absorbs in the load any signal arriving in the reverse direction. It is placed at the output of an amplifier or oscillator to protect it from load reflections, which could damage it, destabilize it or shift its frequency.

Parameters

  • Insertion loss in the forward direction.
  • Isolation in the reverse direction.
  • Return loss of the ports.
  • Bandwidth, which is limited and determined by the design.
  • Maximum power, especially in the isolator’s load, which dissipates the reflected power.

What to watch for

  • Near ferromagnetic materials or magnets, the device’s field and its response are altered.
  • Behavior changes with temperature, because the properties of the ferrite and the magnet depend on it.
  • Orientation matters: installing it backward reverses the direction of isolation.

What an engineer sees

In a network analyzer measurement, S21 and S12 are very different, which confirms the non-reciprocity. If reverse isolation is poor, there may be a defect, a temperature change or a badly terminated load.