How Does a Directional Coupler Work?

It is a four-port component that takes a known fraction of the signal traveling in one direction and delivers it to a coupled port, while almost none of the signal traveling in the opposite direction reaches that port.

Principle

A directional coupler consists of two transmission lines placed close together, so that part of the energy in the main line passes to the secondary line through electric and magnetic field coupling. The arrangement makes the contributions of both couplings add for a wave traveling in one direction and cancel for a wave traveling in the other. That is why it is called directional.

Ports

  • Input. Where the main signal enters.
  • Output or through port. Where most of the signal exits.
  • Coupled port. Delivers a fraction of the signal traveling from input to output.
  • Isolated port. Receives almost no signal from that direction and is usually terminated with a matched load. If the signal is applied in the reverse direction, the roles of the coupled and isolated ports are swapped.

Parameters

  • Coupling. Ratio of the input power to the power at the coupled port, in decibels.
  • Isolation. Ratio of the input power to the power at the isolated port, when driven in the forward direction.
  • Directivity. Difference between isolation and coupling, in decibels. It measures the ability to distinguish between directions.
  • Insertion loss. The small loss between input and output, in addition to the coupled fraction.

What it is used for

It is used to sample power without interrupting the line and to measure reflected power. With a coupler connected in reverse in the line, the coupled port delivers a sample of the reflected wave, so comparing both samples gives the reflection. This is the principle behind reflectometers and the bridges in network analyzers.

What to watch for

Low directivity limits the ability to measure small reflections, because part of the forward wave leaks into the port that should see only the reflected wave. Unused ports must be terminated with good-quality loads, since their reflection alters the result. Coupling varies with frequency, so it is corrected with calibration data. Broadband designs, such as coupled-line types, cover a limited frequency range.