How is the insertion loss of a connector or adapter measured?

By measuring the S21 transmission through a calibrated direct connection and then with the component inserted; the difference is the insertion loss, which includes resistive loss and the effect of mismatch.

What is measured

Insertion loss is the reduction in power a component produces when inserted into a line. In decibels, it is obtained from the magnitude of the S21 transmission with its sign changed. A good connector or adapter has very small values, so the measurement demands care: the measurement error can approach the value itself.

Procedure

  1. Calibrate the analyzer in transmission, with a full two-port calibration or at least a response calibration with a thru, with the reference planes at the connectors where the part will be inserted.
  2. Verify that the thru trace is flat and close to zero decibels.
  3. Insert the adapter between the planes and measure S21.
  4. Also measure S11 and S22 to determine the match of the component.

The problem of different connectors

If the adapter has two connector types, a direct thru cannot be made between the two instrument ports with the same type. There are techniques such as using two identical adapters in series and dividing the result, or the adapter removal method, in which calibration is performed with the adapter and the measurement without it. Both are more complex and must follow the instrument manufacturer’s procedures.

What the result includes

Total insertion loss has two components: the energy dissipated in the component and the energy reflected by mismatch. To separate them, the reflection is measured and the part corresponding to mismatch is calculated. A component with very low dissipative loss can appear to have noticeable loss from reflection alone.

How to interpret the result

  • Loss that increases with frequency is normal in any line.
  • Abrupt variations point to resonances or defective contact.
  • Repeat the connection several times: the spread between connections is the true uncertainty of the measurement, and it is sometimes greater than the loss itself.

Precautions

Clean and inspect the connectors, apply the correct torque and do not move the cables after calibration.