What is the phase noise of an oscillator?

It is the measure of the random phase fluctuations of an oscillator, seen as noise sidebands around the carrier; it is expressed as power in a one-hertz band relative to the carrier, as a function of frequency offset.

What it is physically

An ideal oscillator produces an infinitely thin spectral line. In a real one, the phase of the signal fluctuates randomly because of thermal noise and noise from the active devices, and the carrier energy spreads into a noise skirt on both sides. That skirt is the phase noise.

How it is expressed

It is reported as a curve: the single-sideband noise power in a one-hertz bandwidth, divided by the carrier power, as a function of the offset from the carrier. The unit is dBc/Hz, always with an offset value stated. The values are negative, and more negative means a better oscillator. Noise is higher near the carrier and falls off with distance from it.

Relationship to jitter

In the time domain it appears as instability of the zero crossings, or jitter. Integrating the phase noise over an offset interval makes it possible to estimate the jitter corresponding to that band.

Why it matters

  • Receivers. A noisy local oscillator mixes with strong nearby signals and its noise falls on the weak desired signal. This phenomenon is called reciprocal mixing.
  • Radar and digital communications. It degrades the detection of slow targets and the quality of modulation constellations.
  • Data converters. A noisy clock limits the signal-to-noise ratio at high input frequencies.

How it is measured

  • Direct spectrum analyzer. Simple, but limited by the analyzer’s own phase noise and by its resolution bandwidth. It is suitable for relatively noisy oscillators.
  • Phase detector with a reference. It compares the oscillator in quadrature with another of better quality; it reaches very low noise levels.
  • Cross-correlation. It uses two independent measurement channels to reduce the instrument’s own noise.

What to consider

When interpreting the value, take care that the measurement is not limited by the instrument, that it is normalized to one hertz of bandwidth, and that a distinction is made between phase noise and amplitude noise, which a spectrum analyzer mixes together.