Definition
Return loss compares the reflected power with the incident power at a port and is expressed in decibels. It is calculated as minus twenty times the base-ten logarithm of the magnitude of the reflection coefficient. With that convention the result is positive, and a higher value means less reflection.
- Total reflection: return loss of zero decibels.
- No reflection: infinite return loss.
A problem of conventions
A network analyzer displays S11 in decibels as a negative number, which is the same as twenty times the logarithm of the reflection magnitude. Many users call that negative value “return loss”, and others use the positive value. When reading a data sheet or a result, pay attention to the sign and the wording: “better” always means lower reflection, that is, a more negative S11 or a larger positive return loss. Both names refer to the same quantity.
Relationship to other measures
Return loss, the reflection coefficient and the standing wave ratio describe the magnitude of the same reflection and can be converted into one another. Better return loss corresponds to a VSWR closer to one. It does not contain phase, so it does not say what type of reactance causes the mismatch.
How it differs from insertion loss
Return loss refers to what bounces back at the input. Insertion loss refers to what is lost in passing through a device. A filter can have low insertion loss in its band and at the same time poor return loss, and both must be checked.
How to interpret the result
An antenna with poor return loss at a given frequency is not well matched there and delivers less power to the air. In a cable, return loss that oscillates with frequency indicates distributed reflections, for example at the connectors on both ends. With a long, lossy cable, a measurement from one end looks better than the actual match of the load, because the reflected signal is attenuated on the round trip.