What is the characteristic impedance of a line?

It is the ratio between voltage and current of a wave traveling in a single direction along the line; it depends on the geometry and the dielectric, not on the length, and it determines whether a load produces reflections.

Definition

The characteristic impedance of a line is the ratio between the voltage and the current of a wave propagating in one direction, without reflections. For a line with distributed resistance, inductance, conductance and capacitance per unit length, it is the square root of the quotient of the series impedance and the shunt admittance per unit length. On a lossless line it reduces to the square root of the quotient of the inductance and the capacitance per unit length, and it is a real number.

What it depends on and what it does not

  • It depends on the cross-sectional dimensions and the permittivity of the dielectric. In a coaxial line, on the ratio between the diameters of the inner and outer conductors.
  • It does not depend on length. A short section and a long section of the same cable have the same characteristic impedance.
  • It varies little with frequency on a good-quality line, except at low frequency, where losses carry weight.

Why it matters

If the line ends in a load equal to its characteristic impedance, the wave is completely absorbed and there is no reflection. If not, part of the energy returns, a standing wave forms, and the impedance seen at the input changes with the line length and the frequency. That is why RF systems are designed around a reference value, and 50 ohm and 75 ohm systems are the most widespread by convention, not because of a physical law.

A common misunderstanding

It cannot be measured with an ohmmeter. A DC ohmmeter measures the resistance of the conductor, which is something else. Characteristic impedance manifests itself when a wave is propagating. It is determined with a time-domain reflectometer, with a network analyzer, or from the dimensions and material properties.

What an engineer sees

An impedance discontinuity, for example a poorly mated connector or a change of cable, appears in the time domain as a step in the reflection at the position of the defect, and in the frequency domain as a ripple in the return loss.