What does “ground loop” mean?

It is a closed circuit formed by two or more ground connections of the same signal system; the potential difference between those grounds, or the magnetic flux crossing the loop, drives currents that appear as noise.

Definition

A ground loop appears when a piece of equipment or a signal is connected to the ground reference by more than one path, so that those paths, together with the signal cable, form a closed loop. It is a geometric and electrical condition that has nothing to do with whether the ground is good or bad.

Why it produces noise

  • Potential difference between grounds. Two ground points in an installation are rarely at the same potential when currents are flowing through the system. That difference drives a current through the loop, including the shield of the signal cable.
  • Magnetic induction. A loop with a large area picks up the changing field of nearby conductors, and a voltage is induced in it.

The drop this current causes in the shield or in the signal reference adds to the useful signal.

What is seen in practice

In audio, a hum at the mains frequency and its harmonics. In instrumentation, an unstable baseline or a signal with a periodic mains component. On an oscilloscope, an oscillation at that frequency that changes when cables are moved or when a piece of equipment is connected or disconnected.

How the loop is broken

  • Have a single ground reference for equipment that shares signals, with a star connection.
  • Use differential or balanced inputs, which reject voltages common to both conductors.
  • Isolate the signal with isolation transformers, optocouplers or optical fiber.
  • Reduce the loop area by keeping the outgoing and return cables together.
  • Connect the shield to ground at one end only when the application allows it, although at high frequency it may need to be connected at both ends.

What not to do

Never disconnect the protective ground of a piece of equipment (with adapters that remove it) to eliminate noise. That connection is a safety measure, and removing it can leave the enclosure energized in the event of a fault. The solution is to break the loop in the signal, not in the protection. Measurements and work on energized electrical installations must be performed by qualified personnel, in accordance with applicable regulations and site safety procedures.