What guidance does IEEE 142 give on industrial grounding?

IEEE 142, known as the Green Book, gives guidance on grounding industrial and commercial systems: system grounding, equipment grounding, static, lightning protection and considerations for electronic equipment.

IEEE 142 is a recommended practice for grounding industrial and commercial power systems, that is, installations that are not utility substations but plants, buildings and process centers. It is known as the Green Book because of its cover.

What guidance it gives

  • System grounding: the ways of connecting the neutral (solidly, through resistance, through reactance or with no intentional connection), with their advantages and drawbacks regarding overvoltages, fault currents and continuity of service.
  • Equipment grounding: how to ensure a reliable return path for faults and keep enclosures at a safe potential.
  • Static electricity: practices to avoid charge buildup in processes.
  • Lightning protection: grounding principles applicable to structures and equipment.
  • Sensitive electronic equipment: reference and noise considerations.
  • Construction and measurement: electrodes, connections and system verification.

What engineering decision it helps make

The most relevant one is usually the neutral grounding scheme. A solidly grounded system gives high fault currents and simple detection. A resistance-grounded system limits the fault current and reduces equipment damage, which sometimes makes it possible to continue operating with a first fault. The guide presents the criteria for choosing among these options according to the type of installation.

What it does not aim to be

It is a recommended practice, not the installation code: mandatory requirements are set by local regulations. Nor does it replace the detailed design of a substation grid, which has its own guide.

How to consult it

Given how criteria evolve between editions, the current edition must be reviewed and checked against the requirements of the project and the authority. The design and modification of grounding systems are the responsibility of qualified personnel, in accordance with the applicable safety regulations.