Vacuum and controlled-temperature testing for research and product validation

Tests that combine controlled vacuum, temperature and humidity to validate materials, components and systems under extreme conditions.

Transparent acrylic chamber for vacuum and controlled-temperature testing

Controlled vacuum, temperature and humidity

Our laboratory combines controlled vacuum, temperature and humidity to validate materials, components and systems under extreme conditions. The tests are performed with a high-strength transparent acrylic chamber, an industrial vacuum pump capable of producing extreme vacuum down to 1.7 microns of mercury, and a Sun Electronics Systems environmental chamber.

Vacuum tests

These tests simulate low-pressure environments similar to high altitudes or space. They are useful for evaluating seals, packaging, adhesive joints, porous materials, electronic components and hermetic containers.

The transparency of the acrylic allows direct observation of bubble formation, deformations, collapses and any structural change during the process. Behavior under vacuum reveals defects that do not show up at atmospheric pressure.

The digital measurement system records the vacuum level, internal pressures and their variations during the test. This identifies small leaks, progressive failures, air entry points and unstable behaviors that can compromise product quality in the field.

Temperature tests

The samples can then move to the Sun Electronics Systems temperature chamber, where extreme thermal ranges are applied, from severe cold to high heat. This combination makes it possible to study thermal contraction, expansion, crystallization, coating degradation, loss of adhesion, changes in mechanical properties and non-linear behaviors of advanced materials.

Custom sequences

We also run custom sequences: vacuum followed by thermal cycling, thermal shock under negative pressure, combined structural strength tests and tests with gas injection, depending on the material being evaluated. They serve for research, new product development and failure analysis.

Evidence and report

Each test is documented with photographs, behavior graphs, complete test parameters and technical conclusions written for industrial customers, auditors or engineering departments. We work with real visual evidence, calibrated equipment and procedures designed to obtain repeatable results.