LISN Mate separation network rental for conducted emissions

Rental of the LISN Mate separation network, which breaks conducted noise down into common mode and differential mode for engineers debugging EMC problems.

LISN Mate separation network for conducted emissions analysis

Understanding the origin of conducted noise

In conducted emissions testing, the challenge is not only to measure the noise level but to understand its origin. A conventional LISN gives a signal composed of common mode and differential mode components. That overlap makes it hard to identify the root cause.

The LISN Mate separation network solves that limitation: it breaks the measured signal down into its two components and allows a clearer analysis.

Differentiating modes in EMC

Noise behavior depends on how it travels through the system:

  • Differential mode appears between active conductors and is usually related to the internal operation of the circuit.
  • Common mode couples to ground or nearby structures and is a frequent source of radiated emissions.

Telling them apart makes it possible to apply specific solutions: redesigning current paths, selecting filters or improving shielding.

How it operates

The LISN Mate is used together with two LISNs installed on the power lines of the equipment under test:

  • One LISN connected to the positive line
  • Another LISN connected to the negative line

The device processes both signals and separates them into:

  • Common mode signal
  • Differential mode signal

Each component leaves through an independent BNC output, for direct connection to instruments such as spectrum analyzers.

Value in debugging

  • Quickly identifies the predominant type of interference.
  • Reduces the number of iterations in corrective testing.
  • Improves the selection of mitigation strategies.
  • Makes it easier to comply with regulatory limits.

It is especially useful in product development and in pre-certification processes.

Compatibility with test systems

It integrates into standard conducted emissions measurement setups. It can be used with:

  • Line LISNs
  • Spectrum analyzers
  • EMI receivers
  • RF acquisition systems

It does not change the base measurement method: it extends the system’s analysis capability.

LISN Mate technical specifications

Parameter Specification
Frequency range 30 kHz – 110 MHz
Maximum RF level (per port) 27 dBm
Maximum DC current 30 mA
Connection type Independent BNC
Main function Separation of common and differential mode

Typical applications

It is used where detailed conducted noise analysis is required:

  • Development of switched-mode power supplies
  • Automotive electronics
  • Industrial and control equipment
  • Consumer electronics
  • EMC test laboratories

Benefits of renting

Renting the LISN Mate gives access to advanced analysis capabilities without acquiring it permanently:

  • More precise diagnosis of noise behavior.
  • Optimized engineering time.
  • Greater effectiveness when implementing solutions.
  • Simple integration into existing test benches.
  • Lower costs in validation projects.

This way, conducted emissions problems are addressed with more clarity and the likelihood of regulatory compliance improves from the early stages of development.