ASTM D 445 Kinematic Viscosity Tester for Sale

Kinematic viscometer for petroleum products and transparent and opaque liquids. For lubricant analysis laboratories.

Description

The kinematic viscometer complies with the ASTM D 445 standard. It determines the kinematic viscosity of petroleum products, including transparent and opaque liquids. It measures the volume of liquid flowing by gravity through a calibrated glass capillary viscometer.

Functions and features

  • 5.4-inch LCD screen with Chinese-language menu, and temperature display, humidity measurement and clock.
  • Operation is simple, and it automatically completes the raising, holding, stirring, static setting, calculation, data storage and printing operations.
  • If power is lost, it automatically saves the test results.
  • It has overvoltage, overcurrent, limit and grounding alarms, for the operator’s personal safety.
  • The unique waveform setting function eliminates harmonic interference in the measurement.
  • It is controlled by a dual CPU and a PLC safety instrument, for stable and reliable operation.
  • It has a 232 interface and a Bluetooth function for transmitting data to the computer.

Main technical parameter

Number of liquid bath holes 4
Temperature range Room temperature
Constant temperature accuracy ±0.1°C
Constant measurement accuracy ±0.01°C
Supply voltage 220 V AC ±10%
Power frequency 50Hz ±2%
Power 1500w
Applicable temperature 10~40℃
Applicable humidity <85% RH
Width x height x depth 390×260×240 (mm)
Net weight ~ 18 kg

More functions

  • It uses imported sensors and digital PID temperature control: the control range is wide and the accuracy is high.
  • It has a large color LCD touch screen with simple operation.
  • Any control temperature can be set, from room temperature up to 130 degrees.
  • It automatically saves the test results and can store 100 data sets.
  • Its calendar clock runs without electrical power and automatically starts showing the current time.
  • It offers high accuracy, high speed and stable, reliable data.

What kinematic viscosity is

Kinematic viscosity measures a fluid’s internal resistance to flow under gravitational forces. It is determined by measuring the time, in seconds, that a fixed volume of fluid takes to flow by gravity a known distance through a capillary, inside a calibrated viscometer at a closely controlled temperature. That value is converted to standard units such as centistokes (cSt) or square millimeters per second.

A viscosity report is only valid if the test temperature is also reported, for example, 23 cSt at 40 ºC. Typically, viscosity is reported at 40 °C and/or 100 °C, or at both if the viscosity index must be calculated. It makes no sense to report viscosity for trending without reference to temperature.

Of all the tests for used lubricant analysis, none offers better repeatability or consistency than viscosity. Nor is any property more critical to the efficient lubrication of components than the viscosity of the base lubricant.

Viscosity can be measured and reported as dynamic (absolute) viscosity or as kinematic viscosity. They are easily confused, but they are significantly different. Most used lubricant analysis laboratories measure and report kinematic viscosity. By contrast, most on-site viscometers measure dynamic viscosity but are programmed to estimate and report kinematic viscosity, so that the reports reflect the kinematic numbers reported by most laboratories and lubricating oil suppliers. That is why it is essential for lubricant analysts to understand the difference between the two measurements, especially given the growing popularity of on-site instruments that complement off-site laboratory analysis.

Generally speaking, viscosity is a fluid’s resistance to flow (shear stress) at a given temperature. It is sometimes confused with the thickness (or weight) of the oil. Viscosity is not a dimensional measurement, so calling highly viscous oil “thick” and less viscous oil “thin” is misleading.