24/7 emergencies 814 777 6921812 230 6079WhatsApp 811 786 0768
Electrónica MonterreyElectrónica MonterreyLaboratorios Creativeit Talk to an engineer
Menu

Air Generator for Gas Chromatographs for Sale

Fully automatic air generator that gives gas chromatographs a supply of purified air at stable pressure. For laboratories that use chromatography.

Air generator for gas chromatography

The fully automatic air supply is used specifically with the gas chromatograph, to provide stable pressure and purified air. It is compatible with various gas chromatograph models from domestic and foreign manufacturers.

It has been approved by the National Analytical Instrument Testing Center.

Main technical parameters

Output flow 0-2000ml/min (at 0.4Mpa)
Output pressure 0-0.4Mpa
Pressure stability <0.003Mpa
Working noise <35db(A)
Working environment 0-45 ℃
Relative humidity <85%
Power supply 220V±10%V,50Hz
Power consumption 150W
Outside dimensions 420 mm × 260 mm × 350 mm
Net weight 20Kg

Instrument features

1. Easy operation

Simply switch on the power supply when you need it. Water drains automatically according to ambient humidity.

2. Process advantages

The system is completely closed to increase air purification. Primary and two-stage filters are selected for the same purpose. The pressure setting must be in the 0-0.4Mpa range. Pressure stability has an accuracy better than 0.002Mpa.

3. Long service life

The pressure controller is at the outlet port of the gas storage tank. When the tank pressure falls to the lower limit of 0.6Mpa, the controller starts working. When the pressure reaches the upper limit of 0.8Mpa, the controller cuts the power and the compressor stops. This cycle repeats to meet the requirements of the system. A safety control device prevents overpressure. The system includes a low-pressure starting device that guarantees zero gas pressure every time the main unit starts, which extends its service life.

4. Safe and reliable

Inside the compressor there is an automatic overheating protection device. When the temperature of the compressor’s outer cover exceeds 80 ℃, this device automatically cuts the power supply.

Use and installation

  1. Take the instrument out of the box. Check that the exterior and interior have no serious shipping damage. Then review the instructions and check that the accessories are complete.
  2. Install the air filter parts after the end of the inlet panel. Firmly connect the power line and plug to ensure safety.
  3. Connect the power and turn on the switch; the indicator light comes on. The pressure gauge gradually rises to 0.4Mpa within a few minutes, the compressor stops (water drains from the outlet for about 2 seconds) and the indicator light goes off. If you loosen the sealing nut of the air outlet on panel A, the air escapes and the compressor starts automatically.
  4. Connect an air outlet tube of outside diameter 3 to port A and the other end to the chromatograph, and check that there are no leaks. Outlet port B connects to the inlet of the nitrogen generator (if you do not use port B, seal the holes with the pressure cap). To operate again, simply turn on the power switch.

Points requiring attention

  • If during operation the indicator light comes on and the pressure does not rise to the set value, there are usually two causes: the compressor’s built-in thermal protector is damaged, or the compressor temperature is too high. There may also be a gas leak; to detect it, apply liquid soap throughout the system. When replacing the silica gel, take care of the thread sealing ring, do not trap foreign matter and check that there are no leaks. After the equipment cools down, it may return to normal.
  • To prevent too much water from accumulating, which affects air purity, you can operate the drain switch (drain button on the panel) before shutdown, for the required number of seconds. Watch the drain direction to keep water away from electrical power.
  • Through the observation window you can see the silica gel discoloring and change it when needed. Turn off the power to the equipment and confirm that the pressure indicator is at zero. Turn the drying chamber clockwise and remove it from the instrument. Then unscrew the cap in the opposite direction, replace the silica gel and reassemble in reverse order, checking that there are no leaks.
We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.

Talk to an engineer