Gas chromatography and the hydrogen generator
Gas chromatography (GC) is a common analytical technique for separating and analyzing volatile and semivolatile compounds in a mixture. It combines exceptional resolution with speed and sensitivity. It is applied in the environmental, petroleum, chemical, food (solid and liquid foods) and pharmaceutical industries.
Description
The high-purity hydrogen generator is suitable for various models of gas chromatographs.
Its pressure control uses high-sensitivity fuzzy control and an automatic tracking system, so that pressure stability is better than 0.001 MPa. Hydrogen pressure and flow are therefore stable, and the service life of the instrument is also extended.
Its electrolytic cell uses transition metal catalytic technology and a multi-stage purification process. The instrument includes two filters. Hydrogen purity reaches: oxygen content less than 3PPM and water content dew point temperature -56 ℃.
Main technical parameter
| Hydrogen purity | 99.999%, oxygen content <3 PPM, water content dew point -56 ℃ |
| Hydrogen flow | 0-300ml/minute |
| Output pressure | 0-4Kg/cm2 (about 0.4Mpa) |
| Pressure stability | <0.001MPa |
| Power supply | 220V±10%, 50HZ |
| Power consumption | 150W |
| Ambient temperature | 1-40 ℃ |
| Relative humidity | <85% |
| Outside dimensions | 360×200×260mm |
| Net weight | About 10Kg. |
Instrument features
- Program control. A dedicated chip controls the entire working process. Automatic constant voltage, constant current and hydrogen flow adjust automatically in the 0-300 ml/min range as required.
- Low moisture in hydrogen production. The system uses a membrane separation technique and an effective dehumidification device. Multipolar absorption brings the moisture in the hydrogen down to a dew point temperature of -56 ℃.
- Easy operation. Simply switch on the power supply when you need hydrogen. It can be used continuously or at intervals, and hydrogen production is very stable, with no decay.
- Safe and reliable. The system includes a sensitive, reliable safety device.
How does gas chromatography work?
After the sample is collected and prepared, the analytes of interest are separated inside the column and a detector measures the amount of the components leaving it. In GC, the analyte is injected into the instrument’s sampling port, which leads into an oven where it is vaporized. The flow of inert gas, which is the mobile phase, carries the vaporized sample through a chromatographic column. The compounds partition between the column’s stationary phase and the carrier gas. The strength of the interaction between the compound and the stationary phase determines the analyte’s retention time. At the column outlet, a detector (MS or non-MS) creates a signal as the compounds pass. The result of a GC separation is a chromatogram.
To measure the concentration of an unknown sample, a standard sample of known concentration is injected into the instrument. The peak retention time and area of the standard are compared with those of the unknown sample to determine the unknown concentration. External and internal standards are commonly used in GC for reliable quantification. When the known standards are run separately from the actual sample and their response is compared in another chromatogram, it is an external standard. When the standard is added to the sample and analyzed simultaneously, it is an internal standard.
Sample collection and preparation for GC analysis
Many samples can be analyzed by GC if the compounds are reasonably volatile (they can be vaporized) and thermally stable (they do not degrade at high temperature). They can come from solid, liquid or gaseous materials. When preparing samples for GC, minimize their complexity: sample quality affects the accuracy and precision of chromatographic results. There are matrix-specific preparation techniques for isolating and concentrating the analytes and matrices before analysis.
How to choose a GC column
The GC column is the heart of the system, where the chromatographic separation takes place. Choose the column according to 4 factors: stationary phase, internal diameter (I.D.), film thickness and column length. These factors affect the column’s efficiency, resolution and sample capacity.
The stationary phase should be selected according to the application to be performed.