Equipment for work in confined spaces and hazardous atmospheres
Entering a confined space takes more than a gas detector. You need equipment to assess the atmosphere, maintain ventilation, protect the worker and retrieve them in an emergency.
In Monterrey we rent out specialized equipment that is put together according to the characteristics of each operation. We have equipment with verifiable explosion-proof certification for checking hazardous spaces.
We offer calibrated gas detectors, ATEX fans, ventilation systems, tripods, harnesses, breathing equipment and retrieval accessories, among others.
Equip your operation before entry
A tank, shaft, cistern, vault or industrial vessel can present very different atmospheric and physical hazards. That is why renting lets you choose only the equipment each job needs.
Atmospheric monitoring
Gas detection is one of the first elements to consider before and during the operation. We have calibrated multi-gas detectors, which monitor different parameters depending on the instrument configuration. In industrial applications these may include:
- Oxygen (O₂)
- Hydrogen sulfide (H₂S)
- Carbon monoxide (CO)
- Combustible gases (%LEL)
- Other gases, depending on the detector required
Calibrated equipment makes it possible to measure atmospheric conditions before entry and during the work.
Industrial ventilation for potentially explosive atmospheres
When the area requires ventilation and there is a risk of an explosive atmosphere, we offer ATEX-certified industrial fans to move large amounts of air in a controlled way. With flexible ducts they can be used to:
- Supply air to the interior
- Extract contaminated air
- Renew the atmosphere
- Reduce vapor buildup
- Ventilate tanks and vessels
- Maintain air circulation during maintenance
Equipment must be selected according to the area classification and the conditions of the application.
Access and retrieval systems
When entry is vertical, a suitable retrieval system can be essential. We offer equipment for configuring access and extraction systems:
- Industrial tripods
- Full-body harnesses
- Retrieval systems
- Winches
- Connecting lines
- Fall arrest equipment
With these, an entry and retrieval system is set up to suit the type of space and the operation.
Respiratory protection
Some operations require additional respiratory protection because of contaminants or atmospheric conditions. We have breathing and respiratory protection equipment for industrial applications, subject to the risk assessment and the characteristics of the work.
The right protection depends on the contaminant, its concentration, oxygen availability and the exposure conditions. Not all respirators are appropriate for a confined space.
Complete equipment for industrial crews
You can request only the equipment you need or put together a complete solution.
Example configuration
1. Calibrated multi-gas detector For atmospheric monitoring.
2. ATEX fan + duct For air supply or extraction where applicable.
3. Tripod For vertical access and retrieval.
4. Full-body harness For connection to the retrieval system and fall protection.
5. Retrieval system To extract the worker in an emergency.
6. Respiratory protection According to the risk assessment and atmospheric conditions.
Tanks, shafts, cisterns, vaults and more
- Tank entry
- Cistern cleaning
- Shaft maintenance
- Vault inspection
- Sewer work
- Underground chambers
- Tunnels
- Industrial vessels
- Ducts and hard-to-reach structures
- Industrial plant maintenance
- Construction work
- Inspection and cleaning operations
Do not improvise your equipment
The equipment must match the actual risk of the operation. Before choosing a detector, fan, respirator or retrieval system, consider:
Atmosphere → Gases present → Oxygen → Fire/explosion risk → Access → Depth → Retrieval system → Duration of the work
A suitable rental starts with knowing the site conditions and choosing compatible equipment.
Quotes in Monterrey, Nuevo León
We provide companies and contractors with equipment for atmospheric monitoring, ventilation, protection and retrieval in confined spaces, from a single calibrated multi-gas detector to a complete configuration with ATEX ventilation, tripod, harness and retrieval system.
Tell us:
- Type of confined space
- Approximate depth
- Number of workers
- Type of work
- Duration of the operation
- Whether gases or vapors are known to be present
- Whether access is vertical
- Whether you need ATEX ventilation
With that information we help you define the rental equipment you need.
