24/7 emergencies 814 777 6921812 230 6079WhatsApp 811 786 0768
Electrónica MonterreyElectrónica MonterreyLaboratorios Creativeit Talk to an engineer
Menu

Keysight 16452A Liquid Test Fixture Rental

Rental of the Keysight 16452A Liquid Test Fixture for characterizing the electrical and dielectric properties of liquids with LCR and impedance analyzers, in laboratories, universities and industry.

Diagram of the Keysight 16452A fixture for liquid testing

Fixture for the electrical and dielectric characterization of liquids

Accurately measuring the electrical properties of liquids is essential for materials development, quality control and research. The Keysight 16452A Liquid Test Fixture is used for the dielectric characterization of liquids with LCR and impedance analyzers, providing repeatable, accurate measurements.

At CreativeIT Group we rent out the Keysight 16452A Liquid Test Fixture to research laboratories, universities, materials manufacturers, the electronics, automotive and chemical industries, and companies developing new products.

What the Keysight 16452A is

It is a fixture designed to measure the electrical properties of liquid materials using the impedance technique. Its precision measurement cell minimizes errors caused by stray capacitance and gives repeatable results over a wide frequency range.

It works with small sample quantities and measures with Keysight LCR analyzers and impedance instruments.

Properties that can be measured

  • Relative permittivity (dielectric constant)
  • Complex permittivity
  • Real part (ε’)
  • Imaginary part (ε”)
  • Dissipation factor (Tan Delta)
  • Loss factor
  • Capacitance
  • Conductance
  • Complex impedance
  • Electrical conductivity
  • Electrical resistance
  • DC resistance (depending on the measurement system)
  • Dielectric properties as a function of frequency

Materials that can be analyzed

  • Dielectric oils
  • Mineral oils
  • Synthetic oils
  • Lubricating oils
  • Vegetable oils
  • Coolants
  • Hydraulic fluids
  • Fuels
  • Biodiesel
  • Solvents
  • Alcohols
  • Deionized water
  • Ultrapure water
  • Chemical solutions
  • Electrolytes
  • Liquid resins
  • Liquid adhesives
  • Inks
  • Nanofluids
  • Emulsions
  • Liquid polymers
  • Research materials

Applications

  • Research and development (R&D)
  • Quality control
  • Development of dielectric materials
  • Electronic engineering
  • Electrical engineering
  • Capacitive sensor design
  • Automotive industry
  • Aerospace industry
  • Medical industry
  • Telecommunications
  • RF and microwave materials
  • Universities
  • Research centers

Compatibility

Compatible with Keysight analyzers such as:

  • Keysight E4980A
  • Keysight E4981A
  • Keysight E4990A
  • Keysight E4991B
  • Keysight 4284A
  • Keysight 4294A
  • Other compatible LCR and impedance analyzers

Frequency range

Depending on the analyzer used, the fixture can measure from low frequencies up to several megahertz. This makes it possible to study the dielectric behavior of the material as a function of frequency, along with phenomena such as molecular polarization, dielectric losses and dispersion.

Advantages

  • High accuracy.
  • Excellent repeatability.
  • Low stray capacitance.
  • Easy sample preparation.
  • Requires little liquid volume.
  • Rugged laboratory design.
  • Compatible with materials characterization software.
  • Integrates with automated measurement systems.

Rental service

The rental includes:

  • Keysight 16452A fixture in excellent condition.
  • Functional verification before delivery.
  • Original accessories.
  • Technical advice on installation and setup.
  • Support during the rental period.
  • Daily, weekly and monthly rental options.
  • Shipping throughout Mexico.

We also rent

  • Keysight LCR analyzers.
  • Impedance analyzers.
  • Keysight N1500A Materials Measurement Suite software.
  • Keysight open-ended coaxial probe for liquids.
  • Fixtures for solid materials.
  • Keithley electrometers.
  • Source measure units (SMU).
  • Climatic chambers for temperature and humidity testing.
We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.

Talk to an engineer