Dry-well temperature calibration in Monterrey

Dry-well calibration of thermometers, thermocouples, RTDs, transmitters and other temperature sensors, in the laboratory or at the customer's facilities.

Calibrating a temperature sensor in a dry well with a metal insert

Calibration for thermometers, RTDs, thermocouples and temperature sensors

Temperature is one of the most critical variables in industrial processes. An incorrect measurement can affect product quality, raise operating costs, lead to regulatory non-compliance and compromise process safety. That is why periodic calibration of temperature instruments is essential for reliable, traceable measurements.

At Electrónica Monterrey we perform temperature calibration with a high-precision dry well. The equipment provides a stable, uniform and controlled heat source for verifying thermometers, thermocouples, RTD sensors, transmitters, indicators, controllers and temperature acquisition systems.

We serve the manufacturing, automotive, pharmaceutical, food, petrochemical and energy industries, as well as laboratories, hospitals and research centers.

What is a dry well?

A dry well (Dry Block Calibrator) generates stable, uniform temperatures with a metal block of high thermal conductivity. Unlike liquid baths, it uses no oils or thermal fluids, which makes calibration cleaner, faster, safer and portable.

The sensor is placed in a metal insert designed for it and reaches thermal equilibrium with the block. Its reading is then compared with a certified reference standard to determine the instrument error.

Instruments we calibrate

  • Digital, contact, industrial and laboratory thermometers.
  • Type J, K, T, E, N, R, S and B thermocouples.
  • Pt100 and Pt1000 RTD sensors.
  • Temperature transmitters.
  • Digital indicators.
  • PID controllers.
  • Temperature recorders and data loggers.
  • Data acquisition systems.
  • Industrial process sensors.

What the procedure includes

  • Thermal stability verification.
  • Comparison against a certified standard.
  • Evaluation at multiple temperature points.
  • Determination of the measurement error.
  • Repeatability.
  • Hysteresis (where applicable).
  • Instrument adjustment (if possible).
  • Issue of a technical report.

Calibration in the laboratory or on site

In the laboratory

Instruments are calibrated in a controlled environment, with temperature stability and suitable ambient conditions.

On site

When equipment cannot be taken out of operation or is part of a critical process, we bring the dry well and the reference standards to your facilities. This reduces downtime and logistics costs.

Benefits of the dry well

  • High thermal stability and good temperature uniformity.
  • Fast calibrations.
  • No thermal oils: cleaner and safer.
  • Portability for field work.
  • Wide temperature range.
  • High repeatability.
  • Reliable, traceable results.

Applications

Automotive, food, pharmaceutical, electronics and manufacturing industries; laboratories and hospitals; petrochemicals and refineries; power generation and substations; research centers and universities; HVAC systems and data centers.

Calibration report

Each service includes a technical report with:

  • Identification of the instrument, manufacturer, model and serial number.
  • Measuring range and calibration points.
  • Standard values and measured values.
  • Error obtained and applicable corrections.
  • Ambient conditions and calibration date.
  • Photographic evidence (optional).
  • Technical recommendations.

Advantages of periodic calibration

  • Precise measurements.
  • Fewer production errors.
  • Compliance in quality audits.
  • Metrological traceability.
  • Detection of deviations before they affect the process.
  • Greater instrument reliability.
  • Lower costs from rework or out-of-specification products.
  • Longer equipment service life.

Service throughout Mexico

At Electrónica Monterrey we perform temperature calibration with high-precision instrumentation, specialized technical personnel and documented procedures. We work in the laboratory and at the customer’s facilities, with service throughout Mexico.

We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.

Talk to an engineer