Specialized on-site diagnostics, testing, measurement and maintenance
Industrial electrical systems require periodic inspections, tests and diagnostics to operate safely and reliably. Detecting anomalies in time helps prevent serious failures, reduce maintenance costs and avoid unplanned shutdowns.
At Electrónica Monterrey we provide field services: tests carried out directly at the customer’s facilities by trained technical personnel.
We serve industrial plants, electrical substations, data centers, hospitals, commercial buildings, the automotive, petrochemical and mining industries, power generation, renewable energy and any facility that needs a diagnosis of its electrical systems.
Our field services
Power quality
- Power quality studies.
- Electrical network monitoring.
- Harmonics.
- Flicker.
- Voltage and current imbalance.
- Voltage variations.
- Sags and swells.
- Transients.
- Power factor.
- Electrical event logging.
- Load studies.
- Energy consumption analysis.
Infrared thermography
We carry out thermographic inspections to detect hot spots, loose connections, overloads, defective fuses and damaged circuit breakers. We inspect:
- Transformers.
- Electric motors.
- Electrical panels.
- Motor control centers.
- Busbars.
- Photovoltaic systems.
Field analysis of dielectric oil
- Sample collection.
- Sampling under ASTM standards.
- Visual inspection.
- Temperature measurement.
- Sample preparation for the laboratory.
- Preliminary diagnosis.
Transformer testing
- Turns ratio (TTR).
- Winding resistance.
- Insulation resistance (Megger).
- Polarization index (PI).
- Excitation current.
- Power factor (tan delta).
- Capacitance.
- Frequency response (SFRA).
- On-load tap changer (OLTC) switch test.
- Continuity.
- Polarity verification.
- Comprehensive diagnosis.
VLF testing of medium-voltage cables
- VLF tests.
- Preventive fault location.
- Acceptance tests.
- Post-repair tests.
- Insulation evaluation.
AC and DC hipot testing
- AC hipot.
- DC hipot.
- Insulation verification.
- Acceptance tests.
- Medium-voltage equipment.
- Low-voltage equipment.
Insulation resistance measurement
Applicable to motors, transformers, generators, panels, cables and other electrical equipment.
Polarization index (PI) and DAR
Evaluation of the condition of electrical insulation through standardized tests.
Grounding systems
- Ground resistance.
- Soil resistivity.
- Wenner method.
- Schlumberger method.
- Grounding system continuity.
- Connection verification.
- Lightning protection systems.
- Ground grid studies.
Cable fault location
- Cable tracing.
- Fault location.
- Conductor identification.
- Insulation diagnosis.
Lighting measurement
- Class A and Class B lux meters.
- NOM-025-STPS.
- Evaluation of work areas: offices, industry, hospitals and schools.
Environmental measurement
- Temperature.
- Humidity.
- CO₂.
- Air quality.
- Differential pressure.
- Air velocity.
- Airflow.
- Noise level.
- Vibration.
Capacitor bank inspection
- Physical condition.
- Current.
- Voltage.
- Temperature.
- Harmonics.
- Diagnosis.
Photovoltaic systems
- I-V curves.
- Thermographic inspection.
- Irradiance measurement.
- String verification.
- Module diagnosis.
- Inverter review.
Electric motor testing
- Insulation resistance.
- Polarization index.
- Winding resistance.
- Phase balance.
- Vibration.
- Temperature.
- Current.
Vibration analysis
Evaluation of motors, pumps, fans, compressors, gear reducers and other rotating equipment.
Thickness measurement
Of paints, coatings, galvanizing and protective films.
Borescope inspection
Visual inspection of hard-to-reach areas without disassembling equipment.
Acoustic camera inspection
Detection of compressed air leaks, partial discharges, corona, electric arcing and surface discharges.
Industrial ultrasound
Applied to bearings, valves, leaks, electrical discharges and lubrication.
Electromagnetic field measurement
Exposure evaluation at low frequency, high frequency, radio frequency and microwave frequencies.
Continuity and low-resistance testing
On busbars, cables, connections, circuit breakers and grounding systems.
Predictive maintenance
We integrate several techniques to evaluate the actual condition of assets:
- Thermography.
- Oil analysis.
- Power quality.
- Vibration.
- Ultrasound.
- Electrical measurement.
- Transformer diagnostics.
Sectors we serve
- Automotive industry.
- Manufacturing.
- Energy.
- Electrical substations.
- Hospitals.
- Data centers.
- Food industry.
- Mining.
- Cement plants.
- Petrochemicals.
- Refineries.
- Pharmaceutical industry.
- Shopping centers.
- Hotels.
- Universities.
- Airports.
- Water treatment plants.
- Solar and wind energy.
Why choose Electrónica Monterrey
- Complete portfolio of on-site electrical diagnostic services.
- Measurement equipment from brands such as Megger, OMICRON, Fluke, Hioki, Keysight, Keithley, Megabras, High Voltage Inc. and other internationally recognized manufacturers.
- Technical personnel specialized in electrical testing, predictive maintenance and condition analysis.
- Technical reports with results, photographic evidence, data interpretation and recommendations.
- Service throughout Mexico for industrial, commercial and critical infrastructure projects.
- Field services combined with laboratory analysis for a complete diagnosis of electrical assets.
Benefits for your company
- Fewer unexpected failures.
- Greater equipment availability.
- Lower maintenance costs.
- Longer service life for transformers, motors and electrical systems.
- Compliance with national and international standards.
- Greater safety for personnel and facilities.
- Maintenance planning based on the actual condition of assets.