High-frequency instrumentation and measurement up to 26.5 GHz

RF, microwave and telecommunications measurements up to 26.5 GHz on components, devices and systems, for development, validation and quality control.

High-frequency measuring equipment during radio frequency testing

Precision measurement for radio frequency (RF), microwave and telecommunications

Measuring high-frequency signals is necessary to develop, validate and control the quality of electronic devices. As transmission speeds and operating frequencies increase, specialized instruments are required to measure RF and microwave components and systems with precision.

At Creativeit Labs we offer high-frequency instrumentation and measurement up to 26.5 GHz to characterize electronic components, communication systems and RF devices with accuracy and repeatability. The tests support research projects, product development, failure analysis, prototype validation and quality control.

Services

Measurement with vector network analyzers (VNA)

We characterize devices using S-parameters to understand the electrical behavior of high-frequency components and systems. We evaluate:

  • S11, S21, S12 and S22
  • Return Loss
  • VSWR
  • Impedance matching
  • Smith Chart

Impedance measurement

We determine the complex impedance of electronic components and RF devices to optimize matching between stages and minimize signal losses.

Spectrum analysis

We evaluate radio frequency signals to identify:

  • Operating frequency
  • Harmonics
  • Spurious signals
  • Bandwidth
  • Power level
  • Signal-to-noise ratio (SNR)
  • Electromagnetic interference

RF power measurement

We measure transmit and receive power to verify the performance of wireless communication equipment and modules.

RF filter characterization

We evaluate high-frequency filters to determine:

  • Center frequency
  • Attenuation
  • Insertion loss
  • Out-of-band rejection
  • Selectivity
  • Bandwidth

Antenna characterization

We analyze the electrical performance of antennas with measurements of:

  • VSWR
  • Return Loss
  • Impedance matching
  • Operating band
  • Resonant frequency

Evaluation of RF cables and connectors

We verify the integrity and performance of:

  • Coaxial cables
  • SMA, N-Type, BNC and TNC connectors
  • RF adapters
  • Coaxial assemblies

Characterization of high-frequency components

We evaluate:

  • RF amplifiers
  • Attenuators
  • Power dividers
  • Directional couplers
  • Duplexers and diplexers
  • Oscillators
  • Mixers
  • Passive RF components

Instrumentation

At Creativeit Labs we measure up to 26.5 GHz with:

  • Vector network analyzers (VNA)
  • Spectrum analyzers
  • RF signal generators
  • Power meters
  • High-frequency LCR meters
  • RF probes and accessories
  • Calibration kits
  • Precision adapters and coaxial cables

Applications

Our services are used in projects in telecommunications, wireless networks, 5G, Wi-Fi, Bluetooth, IoT, RFID, GPS, satellite communications, automotive electronics, aerospace, defense, medical electronics, industrial electronics, and research and development (R&D).

Benefits

  • Accurate, repeatable measurements up to 26.5 GHz.
  • Optimized performance of RF and microwave devices.
  • Validation of electronic designs before manufacturing.
  • Early detection of losses, reflections and interference.
  • Reduced development time and costs.
  • Greater reliability in wireless communication systems.
  • Technical support for innovation projects.

Sectors we serve

Electronics, telecommunications, automotive, aerospace, defense, energy, universities, research centers, RF equipment manufacturers and electronic system integrators.

Why Creativeit Labs

  • Instrumentation for measurements up to 26.5 GHz.
  • Engineers specialized in RF, microwave and telecommunications.
  • Custom tests according to the needs of each project.
  • Detailed technical reports with analysis and interpretation of results.
  • Service for research, development, validation and quality control projects.