Fluke 754 rental: process calibrator with HART

Rental of the Fluke 754 Documenting Process Calibrator for calibrating, verifying and diagnosing industrial instrumentation: HART transmitters, RTDs, thermocouples and 4-20 mA loops.

Fluke 754 process calibrator for rent

Multifunction calibrator for process instrumentation

The Fluke 754 sources and measures multiple process variables. It calibrates pressure, temperature, level and flow transmitters, HART instruments, thermocouples, RTDs, 4-20 mA current loops and industrial control equipment. It is used in manufacturing plants, the automotive, pharmaceutical, food and beverage, oil and gas and energy industries, and calibration laboratories.

What the Fluke 754 is

The Fluke 754 Documenting Process Calibrator is a multifunction calibrator for high-precision testing of process instrumentation. It sources, measures and documents electrical and temperature signals, which enables fast, repeatable and traceable calibrations.

It includes HART communication, so you can configure, adjust and calibrate smart transmitters from a single unit, without using several instruments.

Applications

  • Pressure, temperature, level and flow transmitters.
  • 4-20 mA current loops.
  • HART instruments.
  • Pt100 and Pt1000 RTD sensors.
  • Type J, K, T, E, N, R, S and B thermocouples.
  • Process indicators and controllers.
  • PLCs and automation systems.
  • SCADA systems.
  • Instrumentation in chemical and petrochemical plants.

Main functions

Industrial instrumentation calibration

It sources and measures high-precision electrical signals to verify the operation of process instruments.

HART communication

It configures and diagnoses smart transmitters without an additional communicator.

Signal sourcing and measurement

  • Current (mA)
  • Voltage (V and mV)
  • Resistance (Ω)
  • Frequency
  • Pulses
  • Pressure (with Fluke 750P external modules)
  • Temperature via RTD
  • Temperature via thermocouples

Automatic documentation

It stores calibration results in the unit, which reduces data entry errors and makes reporting easier.

Software compatibility

It is compatible with Fluke DPCTrack2 and Fluke MET/TEAM for managing maintenance and calibration history.

Variables it can calibrate

Temperature

  • Pt100, Pt200, Pt500 and Pt1000 RTDs
  • Type J, K, T, E, N, R, S and B thermocouples

Electrical variables

  • Current 0-24 mA
  • 4-20 mA loops
  • DC voltage
  • Millivolts
  • Ohms
  • Frequency
  • Pulses

Process variables

With Fluke 750P pressure modules it can calibrate:

  • Differential pressure
  • Absolute pressure
  • Gauge pressure
  • Vacuum

Why rent it

Renting is an alternative when you need temporary calibrations without a considerable investment.

  • Reduces purchase costs.
  • Equipment ready to use.
  • Useful for scheduled maintenance, audits, validations and plant shutdowns.
  • Available by the day, week or month.

Sectors we serve

  • Automotive industry.
  • Manufacturing.
  • Petrochemicals.
  • Oil and gas.
  • Energy and the electrical industry.
  • Mining.
  • Pharmaceutical industry.
  • Food and beverages.
  • Water treatment.
  • Calibration laboratories and research centers.
  • Industrial automation companies.

Service conditions

  • Genuine Fluke equipment.
  • Equipment inspected before each rental.
  • Technical support and advice on equipment configuration.
  • Immediate availability.
  • Service in Monterrey and throughout Mexico, with nationwide shipping.
  • Rental by the day, week or month.

We also rent

  • Process and pressure calibrators.
  • Pneumatic and hydraulic pumps.
  • Temperature dry wells.
  • Calibration furnaces.
  • Reference multimeters.
  • Clamp meters.
  • Megohmmeters.
  • Power quality analyzers.
  • Oscilloscopes.
  • Thermal imaging cameras.
  • Instrumentation for industrial maintenance.

Frequently asked questions

Does the Fluke 754 include HART communication?

Yes. It can configure and calibrate compatible HART transmitters.

Can I calibrate 4-20 mA transmitters?

Yes. The unit sources and measures current loops.

Can it calibrate RTDs and thermocouples?

Yes. It is compatible with the main types of RTDs and thermocouples used in industry.

Does it include pressure modules?

They are available on request, depending on the pressure range your application requires.

Do you ship?

Yes. We ship equipment throughout Mexico.

Check availability

Ask about availability, rental rates and shipping options to Monterrey and anywhere in Mexico. Talk to the engineer to confirm that the Fluke 754 covers your calibration.

We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.

Talk to an engineer