Environmental chamber and thermal control testing for electronics in Monterrey

Evaluation, qualification and validation of electronic equipment, RF modules, sensors, PCBs and dielectric materials in environmental chambers with temperature and humidity control.

Environmental chamber for thermal control testing of electronic equipment

Environmental and thermal control testing

We perform environmental and thermal control testing to evaluate, qualify and validate electronic equipment, RF modules, sensors, PCBs and dielectric materials. Our environmental chambers control temperatures from -78 degrees up to 300 degrees, with humidity control through ultrasonic humidifiers and cold supply systems. This lets us achieve high and low stress thermal profiles with reproducible control.

Main capabilities

  • Temperature range from ~-80 °C to +300 °C, depending on the configuration and test requirements.
  • Relative humidity controlled between 10% and 95% RH, stable and traceable.
  • Test modes: steady state, programmed ramp, thermal cycling, thermal shock, accelerated aging and storage tests.
  • Powering and mounting of equipment under test (EUT) with cable pass-throughs, access panels and connection to external instrumentation, without degrading the test environment.

Working methodology

  1. Definition of the test profile together with the customer: target temperatures, ramps (°C/min), stabilization times, cycles and humidity levels.
  2. Preparation and conditioning: securing samples, connecting sensors and routing cables, verifying the integrity of the chamber and the purge (when nitrogen is used).
  3. Execution: application of the thermal and/or hygrothermal profile with continuous logging of temperature and humidity using calibrated sensors.
  4. In situ electrical and functional measurement: during stress, the EUT can be monitored with vector network analyzers, real-time spectrum analyzers, impedance analyzers, oscilloscopes, high-accuracy multimeters and noise meters, as required.
  5. Report: we deliver a technical report with an environmental log, time curves, correlated electrical results, photographs of the setup and recommendations.

Applicable standards and references

  • IEC 60068-2-1: low temperature tests.
  • IEC 60068-2-2: high temperature tests.
  • IEC 60068-2-30 / IEC 60068-2-78: humidity and stabilization tests.
  • IEC 60068-2-14: thermal shock test.
  • MIL-STD-810: environmental procedures by military/industrial application (as required).
  • IPC-TM-650 and J-STD-020/033: conditioning of PCBs and moisture-sensitive devices.

Typical applications

Validation of RF modules, evaluation of sensor drift, wireless communications testing in humidity, characterization of attenuation in coaxial cables, accelerated aging of passive components and evaluation of encapsulants against condensation and thermal shock.

Deliverables

  • Detailed technical report with temperature and humidity curves (CSV included).
  • Time-correlated graphs of electrical parameters.
  • Photographs and evidence of the setup.
  • Technical observations and recommendations.

Metrological temperature control

In our environmental analyses and laboratory tests where temperature is a critical parameter, we verify our thermal systems in-house. Each test is backed by temperature validation in our dry-well calibrator:

  • Operating range from -30 °C to 150 °C.
  • Resolution of 0.01 °C.
  • Thermal stability of ±0.02 °C.
  • Display accuracy of ±0.1 °C.
  • Block uniformity (horizontal ≤ ±0.05 °C) and controlled vertical gradient.

This confirms the stability, uniformity and accuracy of the test conditions, with traceable results. The expanded uncertainty of the system is determined according to the operating point, the sensor under test and the process conditions.

All tests are transparent (100%): you may witness them or request videos of all procedures.

We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.

Talk to an engineer