Impedance and material analyzer rental
We analyze radio frequency capacitors and all kinds of materials, such as PCB circuit boards, to determine their relative permittivity.
We have the Agilent HP 4291B impedance and material analyzer in stock for rent or hire. We have fixtures 16190A, 16191A, 16192A, 16193A, 16194A, 15453A and 16454A.
What the HP 4291B measures
- Measures surface-mount components and dielectric and magnetic materials with high accuracy.
- Uses the current-voltage method, which allows very accurate measurements over a wide impedance range.
- Basic accuracy of +/- 0.8%, from 1MHz to 1.8GHz, with 1 mHz resolution.
- Measures permittivity and permeability of materials. Includes Cole-Cole plots and relaxation time analysis.
- Built-in IBASIC to easily control external equipment, such as temperature chambers.
- We have high-temperature heads and fixtures.
- Impedance parameters: |Z|, |Y|, U, R, X, G, B, Cp, Cs, Lp, Ls, Rp, Rs, D, Q.
Analysis service
We analyze passive components such as RF capacitors and inductors with a radio frequency sweep. We also analyze PCB trace width and characterize circuit board materials for RF.
What is the difference between an LCR meter and an impedance analyzer?
Developing and verifying electronic components involves measuring impedance (Z), inductance (L), capacitance (C) and resistance (R). LCR meters and impedance analyzers measure these parameters, but they are not the same.
An LCR meter gives a simple, accurate way to measure impedance in a specific environment or at one frequency point. For components where L, C or R is measured directly, this is often not enough to estimate the full performance of the component. In those cases an impedance analyzer is used, which measures and plots the complex impedance of the device under test over a range of frequencies. A typical analyzer costs considerably more than an LCR meter and is calibrated more precisely before measuring, with a calibration kit.
An LCR meter is used on components that work at a particular frequency, for example those on a data acquisition board or a computer motherboard. When performance must be measured at certain frequencies or with a frequency sweep, an impedance analyzer is used.
From the fundamental measurements, impedance parameters are derived by applying a user-defined equivalent circuit model. These include capacitance, inductance and resistance (hence the name LCR meter), as well as Q factor, dissipation and conductance.
An impedance analyzer includes this functionality and also sweeps the frequency and graphically displays the acquired parameters. LCR meters acquire at a fixed frequency. Some can acquire at several fixed frequencies, and the parameters are then interpolated from the data in an additional step.
We also have the Agilent HP 4263B LCR meter and a wide range of fixtures for SMD, axial and radial components.