Electronic and electrical measurement services and equipment rental in Monterrey
Substation services in Monterrey: general transformer tests
Transformer testing must include electrical tests and tests of the dielectric insulation. All are based on the following standards:
- IEEE C57.12.90-2006. Test code for liquid-immersed distribution, power and regulating transformers.
- IEEE C57.12.00-2006. General requirements for liquid-immersed distribution, power and regulating transformers.
- IEEE C57.106-2006. IEEE guide for acceptance and maintenance of insulating oil in equipment.
- ASTM D 877 D1816. Standard methods for dielectric breakdown voltage.
- ASTM D 971 D2285. Standard methods for interfacial tension of insulating oils.
- ASTM D 1533. Standard method for moisture content in oil.
- ASTM D 974 – D 664 D1534. Methods for acid or neutralization number.
- ASTM D 4059. Method for analysis of PCB content.
The following NTE INEN standards are also taken into account:
- NTE INEN 2111:04. Distribution transformers. Electrical tests.
- NTE INEN 2113:98. Transformers. Determination of losses and no-load current.
- NTE INEN 2114:04. Single-phase transformers. No-load current, loss and short-circuit voltage values.
- NTE INEN 2116:98. Transformers. Impedance and load losses.
- NTE INEN 2117:98. Transformers. TTR transformation ratio, polarity verification.
- NTE INEN 2118:98. Transformers. Winding resistance measurement.
- NTE INEN 2125:98. Transformers. Dielectric tests.
- NTE INEN 2127:98. Transformers. Insulation levels.
As for electrical tests, IEEE C57.12.00-2000 (general requirements for liquid-immersed distribution, power and regulating transformers) divides factory tests into three categories:
- Routine. Quality control tests performed by the manufacturer on each device or on a representative sample, to verify during production that it meets design specifications.
- Design. Tests to determine whether the design of a type, style or model of equipment, or of its parts and components, meets its ratings and operates correctly.
- Other. Tests identified by individual product standards that the purchaser may have specified in addition to routine and design tests. Examples: impulse, insulation power factor and audible sound.
Electrical tests on transformers
Electrical tests verify that transformers meet design specifications. They also provide an initial series of baseline tests to compare with future electrical field tests. The following tests are typically performed on transformers:
Resistance measurement
Checks that all internal winding connections are firmly secured and provides information for determining copper losses.
Transformation ratio
Indicates whether the transformer was built with the correct turns ratio between the primary and secondary windings, and whether it has a suitable percentage differential between taps.
Polarity/phase relation
Checks that the windings are connected as shown on the nameplate.
No-load test
Determines the iron power loss by measuring voltage, current and power in the primary winding. The secondary winding is left open and no current flows through it.
Short-circuit test
Determines the power loss in the primary and secondary windings at rated current. A small voltage is applied to the primary with the secondary short-circuited, which gives the current in each winding.
Temperature rise test
Performed at the factory to determine whether the temperature rises of the windings, oil and other components match the design values.
Applied potential test (Hipot)
The major insulation is subjected to a low-frequency voltage (60 Hz), without exciting the core, for one minute. IEEE C57.12.90 (test code for liquid-immersed distribution, power and regulating transformers) describes the failure mode, such as the presence of smoke or a rise in leakage current.
Impulse tests
These are designed to simulate what the transformer may experience many times during its life cycle:
- A reduced full wave establishes the wave pattern.
- A chopped wave simulates voltage collapse or the discharge of a traveling wave across the surface of an insulator.
- Full waves simulate a distant lightning discharge.
- A front-of-wave simulates a direct lightning strike.
Induced potential test
Tests the insulation system turn to turn and coil to coil, with higher-frequency waves (120 to 400 Hz) to avoid excessive voltages between phases.
Audible sound test
Should be specified when the transformer will be in service in a residential area where noise may be a concern. C57.12.90 gives more information on the test procedures.
Substation test services
- Insulation resistance (megger).
- Contact resistance (ducter).
- Transformation ratio (TTR).
- Winding ohmic resistance.
- Power factor.
- Contact discrepancy tests.
- Dielectric strength tests.
- VLF low-frequency tests.
- Vacuum integrity in circuit breakers.
- Physicochemical tests on mineral oil.
- Gas chromatography tests on mineral oil.
- Chromatography for PCB detection.
- Injection tests on ABB circuit breaker protection units.
- Injection tests on Schneider circuit breaker protection units.
- Injection tests on Siemens circuit breaker protection units.
- Injection tests on Eaton circuit breaker protection units.
- Injection tests on G.E. circuit breaker protection units.
- Injection tests on Merlin Gerin circuit breaker protection units.
- Injection tests on SDD SDF circuit breaker protection units.
- Primary injection.
- CT polarity and saturation.
- Three-phase injection tests on medium-voltage protection relays.
Signal generators up to 26.5GHz in stock
Aeroflex SGA IFR SGA-6
SGA-6 bandwidth: 100 kHz to 6 GHz.
- 13 dBm output (20 dBm optional).
- Low SSB phase noise: -135 dBc / Hz at 1 GHz, at 20 kHz offset.
- Wideband AM, FM, OM, with broad and fully flexible modulation modes (optional).
- Four internal 10 MHz modulation oscillators.
- Internal pulse modulator and generator (optional).
- Comprehensive frequency and amplitude sweep capabilities, including list mode.
- Carrier phase control.
- ILS / VOR and DME avionics options.
- Half-rack width and 4U height, with 8.5-inch touchscreen user interface.
- Synchronization and interaction with S Series modules and instruments.
- AerolockTM interlocking mechanism for multiple instrument applications.
- LAN and GPIB remote control.
- Low cost of ownership thanks to the modular design.
The SGA uses a large touchscreen as its user interface to offer a very easy-to-use signal generator. Thanks to its small form factor, it works equally well in the field, in the laboratory or on a production line. Aeroflex fast low-noise synthesis (FLNS) technology, together with decades of experience in signal source products, ensures that signal purity and integrity are not sacrificed for speed. With its wide range of features and options, the SGA covers the needs of a general-purpose signal generator and offers the high performance demanded by critical receiver measurements or fast manufacturing.
LCR, impedance and material analyzer rental
The Agilent Technologies LCR meter performs fast measurements on components. It is optimized for applications that require precision and versatility, such as benchtop impedance measurement on complex transformers, coils and electrical capacitors. It offers fast, reliable and versatile testing.
Key features and specifications
- 0.1% basic accuracy.
- High-speed measurement: 25 ms.
- DC and six frequencies (100/120/1 k / 10 k / 20 k / 100 kHz).
- Measurement parameters: Z, Y, Theta, R, X, G, B, C, L, D, Q, Rdc, N, M.
Description
The 4263B LCR meter is designed to evaluate components on the production line and for fundamental impedance testing in bench applications. Further features:
- AC test signal level: 20 mV to 1 Vrms in 5 mV steps.
- Internal DC bias (1.5 V, 2 V).
- Test signal level monitor function.
- High-speed contact check.
- Wide capacitance test range.
- OPEN / SHORT / LOAD correction.
- Cable extension up to 4 m.
- Wide availability of accessories.
Configurable options for the Keysight (Agilent / HP) 4263B LCR meter
- 4263B-001: adds the N / M / DCR measurement function.
- 4263B-002: adds a 20 kHz test frequency.
- 4263B-1CN: handle kit.
- 4263B-1A7: calibration conforming to ISO 17025.
Fast performance in system testing
- Maximize testing with fast 25 ms measurements.
- Minimize operator intervention with pass / fail testing.
- Communicate results via display and GPIB.
- Automate testing with the built-in handler interface.
Failure-free results
- Test with confidence using the contact check function.
- Eliminate parasitics with error correction.
- Obtain data with 0.1% basic accuracy.
- Eliminate trigger timing errors with the trigger delay function.
Versatile measurements
- Select from 11 impedance parameters.
- Add three complex transformer parameters with option 4263B-001.
- Adjust the signal level with 5mVrms resolution.
- Monitor actual AC voltage and current levels.
- Choose from many test accessories.
- Save and recall up to ten measurement setups.
High-quality results
- View five digits of data.
- Make accurate measurements with 0.1% basic accuracy.
- Select from 11 impedance parameters.
- Verify device performance under simulated operating conditions.
- Monitor the voltage and current levels of the test signal.
System features for test automation
- Evaluate transformers and coils with option 4263B-001: measure turns ratio, mutual inductance and DC resistance.
- Connect easily with the 16060A transformer test fixture.
- Measure parameter responses at varying signal levels.
- Make electrolytic capacitor measurements.
- Get versatile testing with a wide capacitance range.
- Keep costs low with the built-in DC bias source.
- Protect your investment with high energy protection at the terminals.
- Increase test throughput with fast system measurements.
- Make reliable handler measurements with the contact check function.
