Non-invasive partial discharge monitoring with 64 microphones in Monterrey

We detect, locate and analyze partial discharges with a 64-microphone acoustic camera, without disconnecting the equipment. For maintenance managers of high-voltage equipment.

64-microphone acoustic camera for partial discharge monitoring

Partial discharge detection with an acoustic camera

Why detecting partial discharges matters

Partial discharges (PD) are early signs of electrical insulation degradation and can lead to serious failures if they are not detected in time. Detecting them makes it possible to:

  • Avoid unexpected interruptions in electrical systems.
  • Extend the service life of transformers, cables and high-voltage equipment.
  • Plan preventive maintenance efficiently and safely.

With our 64-microphone acoustic camera, partial discharges can be detected, located and analyzed quickly and accurately.

How it works

  • Each ultrasonic microphone picks up the acoustic waves generated by PD.
  • The system processes the signals in real time and removes interference and ambient noise.
  • A 3D visual map is generated with the exact location of each partial discharge.

Key advantages

  • Non-invasive: safe inspection, without disconnecting the equipment.
  • High resolution: 64 microphones give precise information on each PD point.
  • Immediate results: reports and maps ready for analysis and preventive maintenance.

Why use this method

  1. Safety: avoids contact with high voltage.
  2. Early detection: identifies problems before they become critical failures.
  3. Portability and ease of use: a light, adaptable system for field inspection.
  4. Accuracy and reliability: advanced algorithms filter out noise and deliver reliable data.
  5. Versatility: for energized transformers, cables, breakers and substations.

Recommended applications

  • Power transformers: locates internal discharges and prevents failures.
  • Medium- and high-voltage cables: insulation inspection without interrupting service.
  • Circuit breakers and disconnectors: monitoring of wear and possible PD leakage.
  • Substations in operation: detects discharges while the equipment keeps running.

Technical characteristics

Specification Detail
Microphones 64 high-sensitivity ultrasonic
Processing Real time, noise filtering, 3D acoustic maps
Connectivity USB / Ethernet / Wi-Fi
Software Intuitive visualization, automatic reports
Portability Compact, light and rugged for field use
Safety Non-invasive, compatible with energized equipment

How it is used in practice

  1. Place the camera near the equipment to be inspected.
  2. Each microphone picks up the PD waves emitted by the insulation.
  3. The software processes the signals, filters out noise and generates a location map.
  4. Obtain a report with the intensity and exact location of each discharge.
  5. Plan maintenance with precise, reliable data.