24/7 emergencies 814 777 6921812 230 6079WhatsApp 811 786 0768
Electrónica MonterreyElectrónica MonterreyLaboratorios Creativeit Talk to an engineer
Menu

Electrical Safety Testing of Medical Equipment to IEC60601-1 in Monterrey

Insulation, ground continuity, Hi-Pot and leakage current testing of medical, electronic and portable electrical equipment. For manufacturers, hospitals, laboratories and companies with mains-connected equipment.

Electrical safety test on a medical device in accordance with IEC 60601-1

Electrical safety testing in Monterrey

We perform electrical safety testing of medical equipment, medical electrical equipment, electronic equipment and portable electrical equipment in Monterrey, Nuevo León. The measurement procedures assess insulation integrity, the continuity of protective systems and the electrical currents that can pose a risk to patients, operators and technical staff. Depending on the type of equipment, its construction, its electrical classification and its application, the evaluation may include insulation resistance, protective conductor continuity, dielectric strength (Hi-Pot), leakage current, touch current and other electrical safety checks.

These tests are particularly important for equipment connected directly to the mains that may come into contact with people during operation. An insulation failure, a poor protective connection, a deteriorated cable or a leakage current outside the established values can create hazardous conditions. For that reason the evaluation is carried out with controlled procedures, suitable instrumentation and acceptance criteria that correspond to the type of equipment.

Electrical safety in medical equipment

Medical electrical equipment has particular characteristics because of the interaction between equipment, operator and patient. In certain devices the patient is connected through sensors, electrodes, cables, transducers or other applied parts, so it is especially important to control the currents that can reach those parts.

The electrical safety evaluation verifies different elements of the protection and insulation system and helps identify conditions that would go unnoticed in a visual inspection. The following may require this evaluation:

  • Monitoring equipment.
  • Diagnostic equipment.
  • Laboratory equipment.
  • Therapy equipment.
  • Physiotherapy equipment.
  • Ultrasound equipment.
  • Medical electronic equipment.
  • Medical electrical instrumentation.
  • Power supplies.
  • Measuring equipment.
  • Systems with applied parts.

The specific methodology depends on the architecture and classification of the equipment.

IEC 60601-1

IEC 60601-1 sets general requirements for the basic safety and essential performance of medical electrical equipment. The following may be relevant in an electrical safety evaluation:

  • Protection against electric shock.
  • Insulation.
  • Protective conductor.
  • Leakage currents.
  • Touch current.
  • Currents associated with applied parts.
  • Dielectric strength.
  • Normal operating conditions.
  • Fault conditions.
  • Electrical classification of the equipment.

Not all equipment requires exactly the same tests. The procedures are determined by the design of the device, its classification, its applied parts and the specific scope of the evaluation.

Ground continuity test

Protective conductor continuity is a fundamental check on equipment that uses a ground connection as part of its protection system. The test verifies that there is an adequate electrical path between the protective terminal and the accessible metal parts that must be connected to the protective conductor. A poor connection can increase the impedance of the fault path and affect the protection system. Various accessible metal points on the equipment can be checked.

Some conditions that cause poor results:

  • Damaged conductors.
  • Loose terminals.
  • Deteriorated connectors.
  • Corrosion.
  • Contamination.
  • Incorrect repairs.
  • Damaged power cords.
  • Poor internal connections.

Insulation resistance test

The insulation resistance test assesses the electrical separation between conductive parts and those that must remain insulated. The measurement gives information on the general condition of the insulation and helps identify conditions that can increase leakage currents. Insulation resistance can be reduced by:

  • Aging of materials.
  • Moisture.
  • Contamination.
  • Thermal deterioration.
  • Mechanical damage.
  • Insulation degradation.
  • Surface contamination.
  • Repairs or modifications.

The test voltage is selected according to the equipment and the corresponding procedure, especially on sensitive electronic equipment.

Hi-Pot or dielectric strength test

The Hi-Pot (High Potential) test assesses the ability of the insulation to withstand a given test voltage. A voltage is applied between defined points on the equipment and the response of the insulation is monitored for the established time. It helps detect:

  • Insulation weaknesses.
  • Dielectric breakdowns.
  • Manufacturing defects.
  • Damage caused during a repair.
  • Problems resulting from aging.
  • Defects in insulation systems.

The test voltage, duration and points of application are established according to the characteristics of the equipment and the applicable procedure.

Leakage current measurement

Leakage current is a fundamental parameter of the evaluation. In electronic equipment it can arise from elements such as:

  • EMI filters.
  • Capacitors.
  • Power supplies.
  • Stray capacitances.
  • Interference suppression systems.
  • Internal coupling.

A certain current may therefore be inherent to the design of the equipment and must be evaluated with the corresponding method. In medical equipment the analysis becomes more important when there are applied parts that can touch the patient.

Touch current

Touch current evaluates the currents that may be present on accessible surfaces of the equipment. It is relevant when there are metal or conductive parts that the operator or the patient can touch. The measurement is made under conditions defined to represent the relevant current paths.

Patient current and applied parts

Medical electrical equipment may incorporate applied parts designed to be in contact with the patient. Depending on the classification and configuration of the device, there may be specific requirements for the currents that flow through them. The evaluation must consider:

  • Type of applied part.
  • Connections.
  • Insulation.
  • Leakage currents.
  • Normal conditions.
  • Fault conditions.
  • Interconnection with other equipment.

This is why electrical safety testing of medical equipment requires a more specific evaluation than that of conventional electrical equipment.

Equipment classification

The electrical classification directly influences the test methodology.

Class I equipment

Uses basic insulation together with a protective ground connection. Here it is especially important to evaluate the continuity of the protective conductor and the currents associated with accessible parts.

Class II equipment

Uses double or reinforced insulation as part of its protection system. It does not depend on a protective ground connection in the same way as Class I equipment.

Class III equipment

Designed to operate from a safety extra-low voltage power supply, under the corresponding conditions.

For this reason, the same test procedure must not be applied automatically to all equipment.

Visual safety inspection

Before electrical testing it is advisable to carry out a physical inspection of the equipment. It can reveal problems that must be corrected before certain tests. It includes:

Power cord

Check for cuts, deformation, wear, repairs and deterioration.

Plug and connectors

Verification of physical condition and connections.

Enclosure

Identification of cracks, exposed parts or damage.

Metal parts

Identification of accessible surfaces that may require evaluation.

Labeling

Review of the power, classification and identification information of the equipment.

Portable appliance testing (PAT)

Besides medical equipment, many applications require the electrical safety evaluation of portable equipment and electrical devices used in laboratories, workshops, offices and industrial facilities. This evaluation is known internationally as Portable Appliance Testing (PAT) and may combine:

  • Visual inspection.
  • Protective continuity.
  • Insulation resistance.
  • Leakage current.
  • Polarity, where applicable.
  • Additional evaluations depending on the equipment.

The choice of tests depends on the construction and classification of the device.

Class I equipment and PAT

In Class I equipment the protective connection is fundamental. The evaluation may consider:

  • Protective conductor continuity.
  • Insulation resistance.
  • Leakage current.
  • Condition of the cord.
  • Condition of the plug.
  • Accessible metal parts.

This equipment is found in industrial, commercial and laboratory applications.

Class II equipment and PAT

In Class II equipment, protection depends mainly on double or reinforced insulation. The inspection must pay special attention to:

  • Enclosure.
  • Cables.
  • Insulation.
  • Connectors.
  • Accessible parts.

The electrical tests are selected according to the characteristics of the equipment.

Testing of power tools

Power tools used in industrial maintenance are often exposed to severe conditions:

  • Vibration.
  • Impacts.
  • Dust.
  • Oils.
  • Moisture.
  • Temperature.
  • Frequent use.

We can evaluate:

  • Drills.
  • Grinders.
  • Polishers.
  • Saws.
  • Cutting tools.
  • Portable maintenance equipment.

Periodic inspection makes it possible to detect deterioration before it becomes a hazardous condition.

Testing of laboratory equipment

Laboratories use numerous mains-connected devices, including:

  • Power supplies.
  • Electronic instruments.
  • Measuring equipment.
  • Ovens.
  • Test systems.
  • Computers.
  • Auxiliary equipment.

They may incorporate switching power supplies, EMI filters and various circuits connected to the power input, so the methodology must take their design into account.

Testing after repairs

Repairs can change the electrical characteristics of equipment, for example:

  • Replacement of the power cord.
  • Power supply replacement.
  • Repair of electronic boards.
  • Connector replacement.
  • Enclosure repair.
  • Component replacement.
  • Wiring modifications.

After any intervention it is advisable to repeat the corresponding safety checks before returning the equipment to service.

Electrical safety in maintenance

The tests can be integrated into programs for:

  • Preventive maintenance.
  • Predictive maintenance.
  • Electrical safety.
  • Asset control.
  • Periodic inspection.
  • Equipment management.
  • Maintenance control.

The information obtained makes it possible to build historical records and identify the equipment that requires repair or follow-up.

Documentation and technical report

Depending on the scope of the service, the results are documented in a technical report that may include:

  • Manufacturer.
  • Model.
  • Serial number.
  • Equipment identification.
  • Classification.
  • Evaluation date.
  • Test conditions.
  • Instrumentation used.
  • Tests performed.
  • Values obtained.
  • Applicable acceptance criteria.
  • Observations.
  • Evaluation result.

The documentation maintains a technical history of the equipment and makes follow-up easier in later inspections.

Service applications

Manufacturers

Evaluation of prototypes, production units and repaired equipment.

Hospitals

Maintenance and safety programs for medical equipment.

Laboratories

Evaluation of instruments and mains-connected equipment.

Service centers

Verification of equipment after a repair.

Industrial companies

Evaluation of tools and electrical equipment used by maintenance staff.

Commercial companies

Inspection of electrical equipment used on their premises.

What we offer in Monterrey

We perform electrical safety testing in Monterrey, Nuevo León, for medical, medical electrical, electronic and portable electrical equipment. The service can be adapted to individual evaluations or to multi-equipment programs, according to the needs of each company.

We have experience in electrical measurement, insulation testing, continuity evaluation, high-voltage testing, leakage current analysis and electrical diagnostics, with suitable instrumentation for each application. Our goal is to deliver technical information that makes it possible to identify abnormal electrical conditions, supports maintenance programs and helps keep equipment in suitably safe condition.

If you need insulation, Hi-Pot, ground continuity, leakage current, touch current or electrical safety testing for medical and portable equipment, speak with the engineer. Tell us the model, the type of equipment and the tests you need, and we will tell you which evaluations apply to your equipment.

We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.

Talk to an engineer