Chroma 11800 for ripple current
In the reliability analysis of electronic components, electrolytic capacitors are a critical point because of their sensitivity to ripple current. The Chroma 11800 subjects these devices to controlled electrical conditions to evaluate their performance and service life in demanding scenarios.
The system reproduces AC excitation and DC bias simultaneously, bringing the test closer to real operating conditions in power applications.
Test approach
- Alternating current (ripple): induces heating and internal stress.
- DC voltage: simulates the capacitor operating point.
During the test, variables such as RMS current, effective voltage and peak levels are monitored.
Relevant capabilities
- Current generation up to 30 A
- Test frequencies: 100 Hz to 1 kHz
- Bias of up to 500 V DC
- Monitoring of electrical parameters
- Extended tests with a configurable timer
- Protection systems for safe operation
These features make it possible to run accelerated aging tests and functional validation.
Technical specifications
| Parameter | Specification |
|---|---|
| Ripple current | 0.01 – 30 A |
| Frequency | 100 / 120 / 400 Hz / 1 kHz |
| AC voltage | Up to 90 Vrms |
| DC voltage | 0 – 500 V |
| Current accuracy | ± (0.5% + 0.1% range) |
| Voltage accuracy | ± (0.3% + 0.05 V) |
| Vrms measurement | Up to 200 V |
| Timer | 1 min – 10,000 h |
| Interface | RS-485 |
| Power supply | 180 – 264 VAC |
| Power consumption | 3000 VA |
| Weight | 54 kg |
Typical applications
- Capacitor validation in electronic design
- Tests on switching power supplies and inverters
- Durability testing of power components
- Quality assurance processes
Rental benefits
Renting the Chroma 11800 lets you add specialized testing without investing in high-cost equipment:
- Immediate access to high-demand tests
- Realistic evaluation of component behavior
- Fewer failures in final operation
- Flexible use according to project requirements