Concrete Density Meter: Rebound Hammer

Rebound tester that works on the Schmidt principle to estimate the hardness and compressive strength of concrete, commonly used in construction.

Concrete density meter, rebound hammer

View attached file

Measuring principle

The concrete density meter measures according to the Schmidt principle. It is used mainly in construction and, because it is easy to handle, in other sectors as well, such as checking the hardness of windings.

The test is always performed with the same impact energy of 2.207 J. The initial rebound kinetic energy is shown on the meter as a measure of the hardness of the concrete, the pressure on the surface, or the compressive strength (kg/cm² or its conversion to N/mm²). Concrete quality is assessed mainly by its compressive strength, an indicative value of the load-bearing capacity and durability of concrete structures. Model B works with a considerably lower impact energy, which makes it ideal for testing rather thin elements, with a material thickness of up to 100 mm.

Compressive strength is expressed in figures and letters. For example, B 25 indicates normal concrete with a compressive strength of 25 N/mm². There are different values up to the highest strength class, B 55. With this meter you can classify concrete simply, quickly and accurately. It is supplied factory calibrated; an optional ISO calibration certificate can be requested (additional charge).

Another useful instrument for your measurements on concrete is the concrete moisture meter.

Features

  • Rugged meter
  • Conversion table on the back
  • Long service life
  • Impact energy of 2.207 J / 0.735 J
  • Instructions with correction aid
  • Low weight

Compressive strength of concrete

Compressive strength is generally defined as the resistance to rupture when a compressive load is applied along one axis for a short period. It is determined taking into account the influence of the following quantities:

  • Strength of the cement block
  • Composition and compaction of the concrete
  • Storage time and conditions
  • Dimensions and shape of the test specimen
  • Type and duration of the load

It is normally determined in the laboratory, on concrete cubes or right circular cylinders. On cylinders, once the excess concrete has been removed, it is advisable to apply a capping layer immediately, which is often needed to obtain a smooth, flat bearing surface. The cylinders must harden standing upright.

Since laboratory methods cannot be used in practice, this meter is used, which is easy to handle and considerably accurate. The degree of hardness is obtained from the hardness measurement made with the rebound body.