Megger Rental with PI and DAR for Insulation Resistance Analysis

Rent a megger-type insulation resistance tester with PI and DAR tests, for technicians who repair or maintain electrical and electronic equipment.

Megger insulation resistance tester for rent

Insulation resistance tester

We rent this megger-type resistance tester, an indispensable instrument if you are a technician who repairs electrical and electronic devices.

It measures resistance in a range of 1MΩ to 200GΩ. It also measures voltage, DC or AC, from 10 V to 600 V.

It is practical for measuring the insulation resistance of electrical equipment and of the insulating materials of transformers, motors, cables, switches, electronic devices, etc. It is a good choice if you repair or maintain that equipment.

What are PI and DAR?

  • Polarization Index (PI): the resistance measured at 10 minutes divided by that measured at minute 1 (10 min / 1 min). A result below 2.0 indicates that the insulation is old or dirty.
  • Dielectric Absorption Ratio (DAR): similar to PI, but calculated by dividing the 60-second reading by the 30-second reading (60 s / 30 s). It is ideal for insulation that stabilizes quickly.
  • Accurate diagnosis: both tests eliminate errors caused by changes in ambient temperature during the measurement.

How it works and what it is for

  • It sends high-voltage direct current (such as 500V, 1000V or more) to the electrical components.
  • It measures the result in megohms (MΩ) or gigohms (GΩ).
  • A very high number means the insulation is dry, clean and safe.
  • A low number warns of moisture, wear or damage that can cause short circuits.

Where it is used

  • To check large electric motors and generators.
  • To test underground or industrial electrical and power cables.
  • For maintenance of transformers and control panels.

It has an LCD screen that shows the measured data with good image quality and is easy to read.

Technical specifications

  • Output voltage: 250V/ 500V/ 1000V/ 2000V/ 2500V
  • Measuring range: 250V: 1MΩ to 10GΩ
  • Measuring range: 500V/1000V: 2MΩ to 20GΩ
  • Measuring range: 2000V/2500V: 5MΩ to 40GΩ
  • AC voltage: 10V to 600V
  • DC voltage: 10 V to 600 V.
  • Resistance: 1MΩ to 200GΩ
  • Data storage: 100 sets
  • Operating altitude: 2000 m
  • Operating temperature: 0-35°C
  • Storage temperature: -10 to 50℃
  • Storage humidity: <75% RH
  • Power supply: 8 AA 1.5V batteries
We do real tests, on video! Watch them on our YouTube channel →