Light Meter (Lux Meter) Rental in Monterrey

Rent digital light meters to measure illumination levels in lux and foot-candles. For safety, maintenance and occupational health staff assessing work areas under NOM-025-STPS-2008.

Light meter in Monterrey

We rent digital light meters (lux meters) in Monterrey, Nuevo León, for measuring illumination levels in offices, industrial plants, workshops, warehouses, laboratories, production areas and workplaces. The instrument measures light intensity in Lux (lx) and Foot-Candle (Fc) and is used to assess lighting conditions and for studies related to NOM-025-STPS-2008, Condiciones de iluminación en los centros de trabajo. This Official Mexican Standard sets the minimum illumination levels that must exist in work areas, according to the visual activities performed.

The instrument measures from 0 to 199,900 Lux and up to 18,500 Foot-Candle (Fc), with fast readings directly on its LCD screen. It is useful for lighting studies, internal inspections, facility maintenance and assessments related to the requirements of NOM-025-STPS-2008.

Lighting assessment under NOM-025-STPS-2008

NOM-025-STPS-2008 sets the lighting requirements for workplace areas, to provide suitable conditions for workers’ visual activities. The standard covers the survey of lighting conditions, the assessment of levels, the control and maintenance of existing conditions, and the preparation of the corresponding report.

The assessment can consider different work areas and workstations, and natural lighting, artificial lighting or a combination of both. The standard’s methodology covers the selection of measurement points and methods such as the IES method, the room constant method and measurements at the work plane, depending on the characteristics of the area assessed.

What a light meter is for

A light meter measures illuminance, that is, the amount of luminous flux a surface receives, expressed in lux (lx). The measurement shows objectively whether an area has an illumination level suitable for the visual activity carried out there. It can be used to:

  • Assess lighting in work areas.
  • Check offices and workstations.
  • Measure lighting on production lines.
  • Assess workshops and industrial areas.
  • Check warehouses and storage areas.
  • Measure lighting in corridors and circulation areas.
  • Verify lighting in laboratories.
  • Assess inspection and quality control areas.
  • Identify areas with insufficient lighting.
  • Detect lighting differences between workstations.
  • Carry out studies prior to an inspection.
  • Verify modifications or improvements to the lighting system.
  • Compare luminaires or lighting systems.

Measurement in Lux and Foot-Candle

The instrument lets you select the unit of measurement the study requires.

  • Lux (lx): the unit commonly used in Mexico and in NOM-025-STPS-2008 to express illuminance levels.
  • Foot-Candle (Fc): a unit used mainly in the United States and other measurement systems.

The conversion used by the instrument is 1 Fc ≈ 10.76 Lux. This way you can measure and compare with either unit.

Measuring range and specifications

This light meter measures up to 199,900 Lux, so it is suitable for low illumination levels and for facilities with intense lighting.

Technical specifications

  • Measuring range: 0 – 199,900 Lux
  • Foot-Candle range: 0 – 18,500 Fc
  • Accuracy from 0 to 9,999 Lux: ±(4% + 8)
  • Accuracy from 0 to 999 Fc: ±(4% + 8)
  • Accuracy ≥10,000 Lux: ±(5% + 10)
  • Accuracy ≥1,000 Fc: ±(5% + 10)
  • Accuracy ≥100,000 Lux: ±(5% + 10)
  • Accuracy ≥9,999 Fc: ±(5% + 10)
  • Resolution: 1 Lux from 0 to 9,999 Lux
  • Resolution: 10 Lux for ≥10,000 Lux
  • Resolution: 100 Lux for ≥100,000 Lux
  • Resolution: 1 Fc from 0 to 9,999 Fc
  • Resolution: 10 Fc for ≥10,000 Fc
  • Sampling time: 0.5 seconds
  • Display: 32 × 26 mm LCD
  • Power supply: 3 AAA 1.5 V batteries

Rental for companies in Monterrey

Renting is an alternative when you need a one-off lighting assessment without buying an instrument for permanent use. It is useful for internal inspections, maintenance, commissioning of new facilities, comparing luminaires, or preliminary occupational safety and health studies.

For assessments under NOM-025-STPS-2008, measurements must take into account the operating conditions and the applicable methodology. For example, the STPS sets specific conditions for the stabilization of certain lighting systems before readings are taken, and covers the selection of measurement points according to the characteristics of the area.

What illumination levels NOM-025-STPS-2008 requires

The required levels depend on the visual task and the work area. There is no single mandatory Lux value for all facilities: the standard sets different minimum levels according to the activity. Some examples are circulation areas, offices, industrial processes, inspection, assembly and activities that require greater visual precision.

That is why, in a lighting study, it is advisable to identify what activity is carried out in each area and what its work plane is before comparing the measurements with the values in the standard.

Light meter rental in Monterrey, Nuevo León

If you need to measure the lighting of an office, factory, workshop, warehouse, laboratory or industrial facility, you can rent this light meter in Monterrey to measure illuminance in Lux or Foot-Candle. It is useful for assessments related to NOM-025-STPS-2008 and for maintenance, engineering, industrial safety, diagnostic and facility verification work.

Request availability, rental price and equipment terms.