Power quality and electrical energy analysis in Mexico

Electrical power quality analysis with a network analyzer, for plants with protection trips, voltage failures or recurring breakdowns.

Power quality and electrical energy analysis

Power and energy quality

With state-of-the-art equipment and specialized personnel, we can give you confidence that your analysis will be valid, so that your energy has the expected quality.

According to the standard, electrical power quality is the set of “characteristics of electricity at a given point of an electrical power network, evaluated against a set of technical reference parameters”.

To understand, evaluate and correct incidents in supply quality, a network analyzer with event logging in accordance with Class A (CEI 61000-4-30) must be installed.

A thorough analysis of the electrical parameters of the installation serves as the basis for designing savings measures or implementing technical solutions that correct defects. Before planning the analysis, the following must be evaluated.

Who should carry out a power quality (PQ) analysis?

In general, any electrical installation can potentially be evaluated. These signs point to the need for an analysis:

  • Nuisance tripping of protections
  • Supply voltage failures
  • Recurring breakdowns
  • Abnormal machine performance

It is advisable to approach these analyses as preventive maintenance in scenarios such as:

  • Expansion of the installations
  • Equipment replacement
  • Capacitor bank replacement
  • Installation of sensitive loads (power electronics)

What does a power quality (PQ) analysis achieve?

  • Security of supply: correcting defects achieves optimum network voltage and avoids supply interruptions.
  • Installation safety: you learn the key parameters that define the real capacity of the installation.
  • Reduced energy losses: energy efficiency solutions reduce thermal losses in the conductors.

What good power quality is

Good power quality is neither easy to obtain nor easy to define, because how it is measured depends on the needs of the equipment being supplied. Quality that is good for a refrigerator motor may not be enough for a personal computer. For example, a momentary outage or interruption does not greatly affect motors and lighting loads, but it can cause greater problems for digital clocks or computers.