Digital and vector signal analyzer rental
We have a wide range of RF equipment, with no gimmicks, for immediate delivery from inventory.
Aeroflex SVA Series digital signal analyzer
The SVA Series uses a large touchscreen with context menus that give quick access to measurement parameters. You can split the screen and drag measurements to another window in real time, with a single touch. The touch interface works just as well on a smartphone or tablet.
- Band coverage: SVA-13 from 250 kHz to 13 GHz
- Input level range of +30 dBm
- Maximum instantaneous bandwidth: 90 MHz
- ADC digitizer resolution: 13 bits
- Digital downconverter with sampling rates up to 250 MS / s
- Average noise level: typical -148 dBm / Hz
- Spurious-free dynamic range: 70 dB
- Intermodulation dynamic range: 75 dB
- Sample memory up to 512 MBytes
- Generic modulation analysis and spectrum analysis as standard
- Measurement options for wireless communications testing (includes LTE and 802.11ac)
- Half rack, 4U high, with 8.5-inch touchscreen
- Synchronization and interaction with the SGD signal generator and other S series modules
- Aerolock interlocking mechanism for multiple-instrument applications
- LAN and GPIB remote control
- Low cost of ownership thanks to its modular design
The SVA offers high speed, high linearity, low distortion, wide dynamic range and excellent level accuracy, which gives best-in-class EVM performance. You can trust that the measurement reflects the DUT and not the instrument. Spectrum analysis and generic signal analysis up to 512 QAM come as standard. 2G, 3G, 4G cellular and WLAN a, b, g, n, ac modulation analysis are available as options.
An SVA with Aerolock connected to an SGD signal generator is a very powerful system test tool, the size of a conventional instrument. The Aerolink between the instruments lets them cooperate in measurements.
Network analyzers for rent
We characterize radio-frequency components and systems in Mexico: antennas, amplifiers (noise figure), attenuators, cables, connectors, mixers, transmitters and filters. We measure gain, noise figure, insertion and return loss, and impedance. We also characterize duplexers.
We rent equipment and accessories from immediate inventory. We have different types of network analyzers up to 26.5GHz, with electronic (ECal) and mechanical calibration and verification kits.
If you have never used an RF or vector network analyzer (VNA), renting with a technician included lets you learn how to operate it and determine which model suits your application. We also have calibration kits, verification kits and phase-stable cables. The rental includes a technician experienced with the equipment. We also offer courses on operating a VNA.
We have technicians who are experts in network analyzers. This service has an additional cost, as it does not come with the equipment.
Rent one or several instruments to perform your own measurements and analysis, and avoid the high cost of buying this equipment and its accessories.
Definition
A VNA is an instrument that analyzes the properties of electrical networks, especially the reflection and transmission of electrical signals, known as scattering parameters (S-parameters). It is used most often at high frequencies, between 9 kHz and 110 GHz.
It is widely used in the manufacture of high-power amplifiers and filters for radio-frequency signals, to achieve the required accuracy in the response parameters.
There are also special network analyzers for lower frequencies, down to 1 Hz. They are used, for example, to analyze open-loop stability or to measure audio and ultrasonic components.
There are two main types:
- SNA (Scalar Network Analyzer): measures amplitude properties only.
- VNA (Vector Network Analyzer): measures amplitude and phase. It is much more powerful than the scalar type. It is also called a gain-phase meter or an automatic network analyzer.
Where it is used
In R&D, our vector network analyzers provide measurement integrity to turn knowledge into better designs. On the production line, our VNAs provide the performance and repeatability you need. In the field, portable analyzers deliver high-quality measurements where you require them. Whether you test active or passive devices, on the bench, in the rack or in the field, we can help you.
Connector, verification and calibration kits
We also have connector kits of all types: SMA, N, 3.5 mm, 2.92mm, APC7, 7 mm and BNC. They make working with network analyzers easier.
Connector gauge kits make it possible to accurately measure the critical interface dimensions of most coaxial connectors. Each kit consists of gauges with matched indicators, and the bushings and pins needed to mate with specific connectors. The master gauges zero the dial indicators before measuring the distance from a given interface, for example the shoulder of the male connector, to the mating plane of the outer conductor.
We have verification and calibration kits for the most accurate measurements. The Agilent 85055A verification kit is used to check that a network analyzer operates within its specified performance. All verification kits include measurement data and uncertainties traceable to the US National Institute of Standards and Technology (NIST).
Videos
https://www.youtube.com/watch?v=9xGnTajNrQg
https://www.youtube.com/watch?v=OYrDN2EiWnw
https://www.youtube.com/watch?v=tXA4E67Kabs
https://www.youtube.com/watch?v=V7te08mjUnM
https://www.youtube.com/watch?v=DH3WYKDu8CY
Contact
More information at www.creativeit.com.mx or by phone at 24-59-33-64 and 811-786-07-68. You can also come to our premises, where we will assist you in person.
