Spectrum analyzer rental
At Electrónica Monterrey we give you access to analysis equipment. We are based in Monterrey, but we can ship equipment or travel anywhere in Mexico to perform sweeps or interference analysis.
All rental equipment, electrical and electronic, includes a technician at no extra cost. They are active engineers with field experience on that equipment, who can advise you on the accessories or extras you need to complete your measurements. The equipment is in immediate inventory, with no imports or waiting time: the equipment and the technician are available the same day you contact us. Rent before you buy, to verify its use in real scenarios.
We have portable equipment, such as the Agilent Fieldfox, and benchtop equipment, such as the Agilent ESA and CSA. In the electrical area we rent ducters, megohmmeters, ground resistance and insulation testers, and oil and transformer test machines.
To keep up in the wireless communications market you need tools that can maintain traditional networks and the new 3G and 4G networks being installed. As the market grows, more base stations than ever need service.
What a spectrum analyzer is
It is an electronic measuring instrument that displays on screen the spectral components, across a frequency spectrum, of the signals present at its input. These can be electrical, acoustic or optical waves.
Testing in the electrical area
Electrical tests during commissioning, preventive or corrective maintenance, or diagnostics of electric power distribution equipment verify the condition it is in. Their purpose is to guarantee the continuity and reliability of the electrical distribution system of the plant or company.
Analog and digital analyzers
There are analog and digital spectrum analyzers.
An analog swept analyzer shows the spectral composition of electrical, acoustic, optical, radio-frequency and other waves. Unlike an oscilloscope, it displays waves in the frequency domain rather than the time domain. It can be considered a frequency-selective voltmeter that responds to peaks calibrated in RMS values of the wave. Analog analyzers use a variable-frequency band-pass filter whose center frequency is tuned automatically within a fixed range. A filter bank or a superheterodyne receiver whose local oscillator sweeps a range of frequencies can also be used.
Other analyzers, such as the Tektronix RSA series, are an analog-digital hybrid called a “real-time” spectrum analyzer. Signals are converted to a lower frequency to process them with the FFT or fast Fourier transform, developed by Jean Baptiste Joseph Fourier, 1768-1830.
A digital spectrum analyzer uses the FFT, a mathematical process that transforms a signal into its spectral components. Some measurements require preserving the complete signal, frequency and phase information; this type of analysis is called vector analysis.
Both groups of analyzers can come with an internal generator and be used as a simple network analyzer.
Our inventory of rental spectrum analyzers includes portable equipment for field work and equipment for the laboratory test bench. For those who prefer to own their equipment, we have a selection of refurbished spectrum analyzers for sale and rent. Below is a selection of equipment available for rental, leasing or purchase. If you do not find what you are looking for, contact us.
Available equipment
Agilent E4408B
Performance
- 9Khz to 26.5 Ghz.
- 1.1 dB overall amplitude accuracy.
- 100 Hz to 5 MHz RBW, 100 Hz to 300 Hz optional.
- 7.5 dBm TOI.
- 5-minute warm-up for guaranteed measurement accuracy.
Measurement applications
- Narrow resolution bandwidth, code compatibility with the 8590 series, or 50-ohm tracking generator.
- One-button PowerSuite power measurements, included as standard.
Features
- Rugged, weather-resistant design with snap-on battery pack.
- Large, high-resolution color display.
Video:
https://www.youtube.com/watch?v=NRkNEgL5P_o
Agilent NI996
Frequency coverage
- Frequency range: 100 kHz to 3 or 6 GHz.
- Stimulus/response suite: 10 MHz to 3 GHz or 6 GHz.
- Preamplifier to 3 GHz or 6 GHz.
Performance
- -156 dBm/Hz displayed average noise level (DANL).
- +18 dBm third-order intercept (TOI).
- 0.5 dB overall amplitude accuracy.
- Compact design, 7.5 kg.
- 2+ hours of battery life.
Features
- Channel power measurements.
- Optional AM/FM modulation analysis.
- RBW adjustable in 10% steps from 10 Hz to 200 kHz, 250 kHz, 300 kHz, 1 MHz, 3 MHz and 5 MHz; VBW from 1 Hz to 8 MHz.
Video:
https://www.youtube.com/watch?v=gcBtiSn-4Lo
Agilent Fieldfox N9912A
Agilent Fieldfox N9912 with:
- Interference Analyzer
- Vector Network Analyzer
- Power Meter
- Cable and Antenna Analyzer
- Vector voltmeter
- Preamplifier for the spectrum analyzer
- Quick cal.
Videos:
https://www.youtube.com/watch?v=jtnNM2nbD_w
https://www.youtube.com/watch?v=n-CTA6bVW4Y
Tektronix 492BP
The 492 Portable Spectrum Analyzer is a rugged, high-performance, microprocessor-aided, compact instrument with automatic modes. Its three-button operation is as simple as 1, 2, 3, through microprocessor-coupled functions: resolution bandwidth, video bandwidth, sweep time, frequency range, RF attenuation and reference level.
This portable analyzer covers 50 kHz to 21 GHz (up to 220 GHz with optional waveguide mixers, sold separately). It offers fully calibrated amplitude and frequency, with CRT readout of all important parameters, for operator convenience and fast setups. Amplitude comparison in 0.25 dB steps. 80 dB dynamic range. Its resolution bandwidth runs from 1MHz to 1kHz in decade steps, plus an auto position. Resolution is within 20% of the selected bandwidth.
Options
- Option 01: calibrated internal preselection. Input filtering to the first mixer for each frequency band.
- Option 02: digital storage. With Save A, max hold, B minus Save A, display averaging and storage bypass.
- Option 03: frequency stabilization with 100 Hz resolution. Provides first local oscillator stabilization by phase-locking the oscillator to an internal reference.
Features
- Center frequency: 10KHz to 21GHz with internal mixer, 325GHz with optional WM490 series mixers.
- Built-in frequency counter.
- Resolution bandwidth (6dB): 100Hz to 3MHz.
- Frequency span/div range: 0Hz, 100Hz to 10GHz (up to 10GHz in waveguide bands).
- Automatic noise normalization to 1Hz and conversion to reference units in dBm, dBmV, dBV, dBuV and dB/Hz.
- Digital storage.
- Tracking preselector.
- Direct plotting capability.
- Non-volatile memory (stores up to 9 waveforms and 10 front-panel setups).
- Fully programmable GPIB.
Specifications
- Upper frequency limit: 21.00GHz.
- Resolution bandwidth Max.3MHz.
- Resolution bandwidth Min.100Hz.
- Amplitude range: 117 to +30 dBm.
We have a wider variety of equipment in stock to fit your budget. We keep continuous business hours.
