Fluke 1732 rental: three-phase energy and power quality logger

Fluke 1732 Energy Logger three-phase energy logger for energy audits, efficiency studies and load analysis in industrial and commercial facilities.

Fluke 1732 Energy Logger for rent

The Fluke 1732 Energy Logger is a three-phase energy logger for measuring, recording and analyzing electricity consumption in industrial, commercial and institutional facilities. It is used for energy audits, efficiency studies, load analysis and electricity consumption optimization projects.

At Creativeit we rent out the Fluke 1732 with units that are calibrated and ready to install. The measurements make it possible to identify energy-saving opportunities, verify consumption and document the performance of electrical systems.

Applications

  • Energy audits.
  • Energy efficiency studies.
  • Electricity consumption measurement.
  • Monitoring of three-phase loads.
  • Identification of high-consumption equipment.
  • Evaluation of industrial electrical systems.
  • Verification of motor and machinery performance.
  • Studies ahead of energy-saving projects.
  • Monitoring of commercial and industrial buildings.

Parameters logged

It continuously logs:

  • AC voltage.
  • AC current.
  • Active power (kW).
  • Reactive power (kVAR).
  • Apparent power (kVA).
  • Power factor.
  • Energy consumed (kWh).
  • Frequency.
  • Electrical demand.
  • Load balance between phases.

Main features

  • Logging of single-phase and three-phase systems.
  • Simultaneous measurement of voltage, current and power.
  • Internal memory for long-duration logging.
  • High-resolution color display.
  • Easy setup through an intuitive interface.
  • Compatible with Fluke Energy Analyze software.
  • Rugged, portable design for industrial use.

Benefits of renting a Fluke 1732

  • Fast installation without interrupting operations.
  • Continuous logging for hours or several days.
  • Fluke Energy Analyze software for data download and analysis.
  • Ideal for electricity consumption audits.
  • Avoids buying the instrument.
  • Available for temporary projects and specialized studies.

When to rent a Fluke 1732

Renting makes sense for temporary electricity consumption studies, energy audits, efficiency analysis or load monitoring without investing in specialized equipment. It is useful for companies, contractors, consultants and engineers who need reliable information to optimize energy use.

What the rental includes

  • Calibrated Fluke 1732 unit.
  • Complete set of voltage test leads.
  • Flexible current probes (Rogowski).
  • Charger and accessories.
  • Memory for data storage.
  • Advice on correct installation of the equipment.

Request a quote

At Creativeit we rent out energy analyzers and loggers for industrial projects, energy audits and electrical studies throughout Mexico. Contact us for technical advice and a personalized quote.